Abstract

Bleaching agents may affect surface properties of mineral trioxide aggregate (MTA) as a coronal barrier. The purpose of this study was to investigate surface properties of MTA after exposure to intracoronal bleaching agents. MTA was set in acrylic molds with a 4 mm high central hole and a 6 mm diameter. Specimens were divided into four groups (n = 10); three groups were exposed to bleaching agents three times on every fourth day (carbamide peroxide-CP, hydrogen peroxide-HP, sodium perborate-SP) and a control group-C. The surface roughness and Vickers surface microhardness were measured. Differences between groups were analyzed using a Kruskal-Wallis test and intergroup comparisons were assessed with a Mann-Whitney U test with a Bonferroni correction (p < 0.0001). The microstructure and elemental composition were observed using a scanning electron microscope (SEM) and an energy-dispersive X-ray microanalysis (EDX) system. In terms of microhardness, the decrease in the HP group was significantly greater than that of the CP and SP groups; CP group significantly greater than that of the SP group, however, there was no significant difference between the SP and C groups. Surface roughness values were compared between groups, and no significant differences were observed between the CP and HP groups, and they exhibited significantly higher roughness values than the SP and C groups. SEM/EDX showed that the bleaching agents affected the elemental distribution. Bleaching agents adversely affected the surface roughness, surface microhardness and elemental distribution of MTA, with exposure to SP causing fewer changes on the surface properties than CP or HP.

摘要

漂白剂可能会影响矿物三氧化物聚合体(MTA)作为冠部屏障的表面性能。本研究旨在研究暴露于根管内漂白剂后 MTA 的表面性能。MTA 被放置在带有 4mm 高中心孔和 6mm 直径的丙烯酸模具中。将标本分为四组(n=10);三组每隔四天暴露于漂白剂三次(过氧脲-HP、过硼酸钠-SP),对照组-C。测量表面粗糙度和维氏表面显微硬度。使用 Kruskal-Wallis 检验分析组间差异,并使用带有 Bonferroni 校正的 Mann-Whitney U 检验评估组间比较(p<0.0001)。使用扫描电子显微镜(SEM)和能谱 X 射线微分析(EDX)系统观察微观结构和元素组成。在显微硬度方面,HP 组的下降明显大于 CP 和 SP 组;CP 组明显大于 SP 组,但 SP 组与 C 组之间无显著差异。对各组的表面粗糙度值进行比较,CP 组和 HP 组之间无显著差异,它们的表面粗糙度值明显高于 SP 组和 C 组。SEM/EDX 显示,漂白剂会影响元素分布。漂白剂会对 MTA 的表面粗糙度、表面显微硬度和元素分布产生不利影响,与 CP 或 HP 相比,SP 对表面性能的影响较小。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验