Suppr超能文献

用于长期心电图记录的柔性碳纳米管基聚合物电极。

Flexible Carbon Nanotube-Based Polymer Electrode for Long-Term Electrocardiographic Recording.

作者信息

Chi Miao, Zhao Jingjing, Dong Ying, Wang Xiaohao

机构信息

Graduate School at Shenzhen, Tsinghua University, University Town of Shenzhen, Shenzhen 518055, China.

Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, University Town of Shenzhen, Shenzhen 518055, China.

出版信息

Materials (Basel). 2019 Mar 23;12(6):971. doi: 10.3390/ma12060971.

Abstract

The long-term monitoring of electrocardiogram (ECG) is critical for the accurate diagnosis and tracking of cardiovascular diseases (CVDs). However, the commercial Ag/AgCl electrode is not suitable for long-term monitoring due to skin allergies and signal degradation, caused by the conductive gel drying over time. In this paper, a flexible gel-free electrode, composed of a multi-wall carbon nanotube (MWCNT) and polydimethylsiloxane (PDMS), is proposed for long-term wearable ECG monitoring. To achieve uniform dispersion of MWCNTs in viscous PDMS, we developed a novel parallel solvent-assisted ultrasonic dispersion method, wherein the organic solvent n⁻Hexane served as a dispersion to avoid MWCNT aggregates. The properties of the MWCNT/PDMS electrode were assessed through structural characterization, contact impedance tests, ECG measurements, and biocompatibility tests. When the MWCNT weight fraction reached 5.5 wt%, the skin-electrode contact impedance of the MWCNT/PDMS electrode was lower than that of the Ag/AgCl electrode below 100 Hz. In daily ECG monitoring, the MWCNT/PDMS electrodes showed superior performance against motion artifact compared to the Ag/AgCl electrode. After seven days of wearing the MWCNT/PDMS electrode, ECG signals did not degrade and no side effects, such as skin redness and swelling, were observed. Thus, this electrode could enable long-term ECG monitoring in wearable healthcare systems.

摘要

心电图(ECG)的长期监测对于心血管疾病(CVD)的准确诊断和跟踪至关重要。然而,商用银/氯化银电极由于皮肤过敏以及随着时间推移导电凝胶干燥导致的信号退化,并不适合长期监测。在本文中,提出了一种由多壁碳纳米管(MWCNT)和聚二甲基硅氧烷(PDMS)组成的柔性无凝胶电极,用于长期可穿戴式ECG监测。为了使MWCNT在粘性PDMS中均匀分散,我们开发了一种新型的平行溶剂辅助超声分散方法,其中有机溶剂正己烷用作分散剂以避免MWCNT聚集。通过结构表征、接触阻抗测试、ECG测量和生物相容性测试对MWCNT/PDMS电极的性能进行了评估。当MWCNT重量分数达到5.5 wt%时,MWCNT/PDMS电极在100 Hz以下的皮肤-电极接触阻抗低于银/氯化银电极。在日常ECG监测中,MWCNT/PDMS电极相对于银/氯化银电极在抗运动伪影方面表现出优异的性能。佩戴MWCNT/PDMS电极七天后,ECG信号没有退化,也未观察到皮肤发红和肿胀等副作用。因此,这种电极能够在可穿戴医疗保健系统中实现长期ECG监测。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验