Suppr超能文献

密理博拭子-膜过滤器试剂盒的评估

Evaluation of Millipore Swab-Membrane Filter Kits.

作者信息

Devenish J A, Ciebin B W, Brodsky M H

机构信息

Ontario Ministry of Health, Laboratory Services Branch, Box 9000, Terminal A, Toronto, Ontario, Canada M5W 1R5.

出版信息

J Food Prot. 1985 Oct;48(10):870-874. doi: 10.4315/0362-028X-48.10.870.

Abstract

A laboratory performance evaluation was done on the Millipore Total-Count (TC) and SPC swab-membrane filter kits which are designed to monitor sanitary conditions on food contact surfaces and eating utensils. Hand-shaking was as effective as vortexing for dislodging bacteria from the cotton swab in vials of Millipore buffer, but bacteria were unstable in the Millipore buffer even when refrigerated at 4°C. These results indicate that the Millipore swab-membrane filter kits could be used by public health officials but both swabbing and sampling should be completed in the field and the samplers returned to the laboratory for incubation, enumeration and proper disposal. Compared to the standard pour plate, recovery of unstressed Escherichia coli cells by the TC sampler was accurate provided not more than 125 colonies were on the membrane filter of the sampler. In comparing the two kits for recovery of stressed bacteria, the Millipore TC sampler was able to recover chlorine-stressed but not heat-stressed cells, whereas the opposite results were obtained with the SPC sampler. Hence, the availability of two different Millipore kits, neither of which recovers all types of stressed bacterial cells, indicates the need for designing a newer media formulation that could accomplish this effectively using just one sampler. Once these criteria have been met, the Millipore swab-membrane filter kit could replace the more tedious and time-consuming standard method currently used for monitoring sanitary conditions related to public health.

摘要

对密理博全计数(TC)和标准平板计数(SPC)拭子 - 膜过滤试剂盒进行了实验室性能评估,这些试剂盒旨在监测食品接触表面和餐具的卫生状况。在密理博缓冲液小瓶中,通过手动振荡从棉签上洗脱细菌的效果与涡旋振荡一样好,但即使在4°C冷藏时,细菌在密理博缓冲液中也不稳定。这些结果表明,公共卫生官员可以使用密理博拭子 - 膜过滤试剂盒,但拭子采样和样本采集都应在现场完成,然后将采样器送回实验室进行培养、计数和妥善处理。与标准倾注平板法相比,只要采样器的膜过滤器上的菌落不超过125个,TC采样器对未受胁迫的大肠杆菌细胞的回收率就是准确的。在比较两种试剂盒对受胁迫细菌的回收率时,密理博TC采样器能够回收受氯胁迫但不受热胁迫的细胞,而SPC采样器则得到相反的结果。因此,两种不同的密理博试剂盒都不能回收所有类型的受胁迫细菌细胞,这表明需要设计一种更新的培养基配方,仅使用一种采样器就能有效地实现这一目标。一旦满足这些标准,密理博拭子 - 膜过滤试剂盒就可以取代目前用于监测与公共卫生相关的卫生状况的更繁琐、耗时的标准方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验