Suppr超能文献

局部合成骨源性羟基磷灰石与Medpor®眼眶植入物在动物模型中的临床结果与病理检查比较

Comparison of Clinical Results and Pathological Examinations Between Locally Synthesized Bone-derived Hydroxyapatite and Medpor® Orbital Implants in Animal Models.

作者信息

Roslinah Muji, Wan Hitam Wan-Hazabbah, Md Salleh Md Salzihan, Abdul Hamid Suzina Syeikh, Shatriah Ismail

机构信息

Ophthalmology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, MYS.

Pathology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, MYS.

出版信息

Cureus. 2019 Jan 25;11(1):e3954. doi: 10.7759/cureus.3954.

Abstract

We aimed to compare clinical and pathological reactions towards locally synthesized bovine bone derived from hydroxyapatite (bone docosahexaenoic acid (dHA)) and commercially available porous polyethylene (Medpor®, Porex Surgical Incorporation, Georgia, USA) orbital implants in animal models. An experimental study was performed on 14 New Zealand white rabbits. Group A (n=7) was implanted with bovine bone dHA and group B (n=7) was implanted with Medpor®. Clinical examinations were performed on Days 1, 7, 14, 28, and 42 post-implantation. The implanted eyes were enucleated on Day 42 and were sent for pathological evaluation. Serial clinical examinations included urine color and odor; feeding and physical activity demonstrated normal wellbeing in all the subjects. Localized minimal infection was observed in both groups during the first two weeks following implantation, and the subjects responded well to topical moxifloxacin. Both groups exhibited evidence of wound breakdown. No signs of implant migration or extrusion were observed in either group. The histopathological examination revealed no statistically significant difference in inflammatory cell reactions and fibrovascular tissue maturation between both types of implants. However, all (100%) of the bovine bone dHA implants displayed complete fibrovascular ingrowth compared to Medpor® implants (57.1%) at six weeks post-implantation (p=0.001). In conclusion, bovine bone dHA and Medpor® orbital implants were well-tolerated clinically and displayed similar inflammatory reactions and fibrovascular tissue maturation. Locally synthesized bovine bone dHA orbital implants displayed significantly greater complete fibrovascular ingrowth in comparison with Medpor® implants.

摘要

我们旨在比较在动物模型中,局部合成的源自羟基磷灰石的牛骨(骨二十二碳六烯酸(DHA))与市售多孔聚乙烯(Medpor®,美国佐治亚州Porex Surgical Incorporation公司)眼眶植入物的临床和病理反应。对14只新西兰白兔进行了一项实验研究。A组(n = 7)植入牛骨DHA,B组(n = 7)植入Medpor®。在植入后第1、7、14、28和42天进行临床检查。在第42天摘除植入眼并送去进行病理评估。系列临床检查包括尿液颜色和气味;进食和身体活动表明所有受试对象健康状况正常。植入后的前两周内,两组均观察到局部轻微感染,受试对象对局部使用莫西沙星反应良好。两组均出现伤口裂开迹象。两组均未观察到植入物迁移或挤出的迹象。组织病理学检查显示,两种类型的植入物在炎症细胞反应和纤维血管组织成熟方面无统计学显著差异。然而,在植入后六周时,所有(100%)牛骨DHA植入物均显示完全的纤维血管长入,而Medpor®植入物的这一比例为57.1%(p = 0.001)。总之,牛骨DHA和Medpor®眼眶植入物在临床上耐受性良好,且表现出相似的炎症反应和纤维血管组织成熟。与Medpor®植入物相比,局部合成的牛骨DHA眼眶植入物显示出显著更高的完全纤维血管长入。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7024/6436666/9d54c16abdab/cureus-0011-00000003954-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验