Suppr超能文献

在Minicare平台上用于即时诊断的单表位B型利钠肽夹心免疫测定法的分析性能

Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics.

作者信息

Reenen Alexander van, Berger Mario, Moreau Emmanuel, Bekx Edwin, Bruinink Tom, Kemper Danielle, Lippen Lian van, Weusten Jos, Mrakovic Anita, Michielsen Etienne, Vissers Joost, Theije Femke de, Nieuwenhuis Jeroen, Semjonow Veronique, Mair Johannes

机构信息

Minicare BV, Eindhoven, the Netherlands.

Philips BG Emerging Businesses, Eindhoven, the Netherlands.

出版信息

Pract Lab Med. 2019 Mar 17;15:e00119. doi: 10.1016/j.plabm.2019.e00119. eCollection 2019 May.

Abstract

Point-of-care B-type natriuretic peptide (BNP) testing with adequate analytical performance has the potential to improve patient flow and provide primary care givers with easy-to-use advanced diagnostic tools in the management of heart failure. We present the analytical evaluation of the Minicare BNP immunoassay under development on the Minicare I-20 platform for point-of-care testing. Analytical performance was evaluated using EDTA venous whole blood, EDTA plasma and capillary whole blood. Method comparison with a lab-testing system was performed using samples from 187 patients. Normal values were determined based on 160 healthy adults, aging from 19 to 70 years. Limit of blank (LoB), limit of detection (LoD) were determined to be 3.3 ng/L, 5.8 ng/L. Limit of quantitation (LoQ) in whole blood at 20% and 10% coefficient of variation (CV) was found < 9 ng/L and <30 ng/L respectively without significant differences between EDTA whole blood and EDTA plasma. Total CV was found to be from 6.7% to 9.7% for BNP concentrations between 92.6 and 3984 ng/L. The sample type comparison study demonstrated correlation coefficients between 0.97 and 0.99 with slopes between 1.03 and 1.09 between the different samples. Method comparison between Minicare BNP and Siemens ADVIA Centaur BNP demonstrated a correlation coefficient of 0.92 with a slope of 1.06. The 97.5% URL of a healthy population was calculated to be 72.6 ng/L. The Minicare BNP assay is a robust, easy-to-use and sensitive test for rapid determination of BNP concentrations that can be used in a near-patient setting.

摘要

具有足够分析性能的即时检测B型利钠肽(BNP),有潜力改善患者流程,并为初级护理人员提供易于使用的先进诊断工具,用于心力衰竭的管理。我们展示了在Minicare I-20平台上正在开发的用于即时检测的Minicare BNP免疫测定法的分析评估。使用乙二胺四乙酸(EDTA)静脉全血、EDTA血浆和毛细血管全血评估分析性能。使用187例患者的样本与实验室检测系统进行方法比较。基于160名年龄在19至70岁之间的健康成年人确定正常值。空白限(LoB)、检测限(LoD)分别确定为3.3 ng/L、5.8 ng/L。发现全血中20%和10%变异系数(CV)时的定量限(LoQ)分别<9 ng/L和<30 ng/L,EDTA全血和EDTA血浆之间无显著差异。对于92.6至3984 ng/L的BNP浓度,总CV为6.7%至9.7%。样本类型比较研究表明,不同样本之间的相关系数在0.97至0.99之间,斜率在1.03至1.09之间。Minicare BNP与西门子ADVIA Centaur BNP之间的方法比较显示相关系数为0.92,斜率为1.06。健康人群的97.5%医学决定水平(URL)计算为72.6 ng/L。Minicare BNP测定法是一种强大、易于使用且灵敏的检测方法,可快速测定BNP浓度,可用于床旁检测。