Cardiac output in exercise by impedance cardiography during breath holding and normal breathing.

作者信息

Du Quesnay M C, Stoute G J, Hughson R L

出版信息

J Appl Physiol (1985). 1987 Jan;62(1):101-7. doi: 10.1152/jappl.1987.62.1.101.

DOI:10.1152/jappl.1987.62.1.101
PMID:3104280
Abstract

Estimation of cardiac output by impedance cardiography (QZ) in exercise during normal breathing (NB) has been limited by motion artifact. Our objective was to obtain readable impedance cardiograms on five subjects during upright cycle exercise at 0, 50, 100, 150, and 200 W to permit comparisons of QZ during NB, expiratory breath hold (EXP) and inspiratory breath hold (INSP). Q was also determined using an equilibration CO2 rebreathing method [Q(RB)]. QZ during NB exceeded EXP QZ at 100, 150, and 200 W, and exceeded INSP QZ at 100 W (P less than 0.05). The low EXP QZ values were due to a significantly lower stroke volume at 100, 150, and 200 W (P less than 0.05). For the INSP QZ at 100 W, heart rate was lower than during EXP (P less than 0.05). Regression of QZ (NB) against Q(RB) resulted in a linear relationship (r = 0.93) over the range of Q = 7-26 1/min. The slope of the regression differed significantly from 1.0 (P less than 0.05). We conclude that QZ values obtained during EXP or INSP should not be assumed to represent QZ during NB, at least at work rates greater than 50 W. A consequence of the linear relationship between QZ(NB) and Q(RB) over the range of 0-200 W is that estimates of CO2 rebreathing cardiac output can be obtained by impedance cardiography if QZ is adjusted using an appropriate empirical factor.

摘要

相似文献

1
Cardiac output in exercise by impedance cardiography during breath holding and normal breathing.
J Appl Physiol (1985). 1987 Jan;62(1):101-7. doi: 10.1152/jappl.1987.62.1.101.
2
Determination of cardiac output using ensemble-averaged impedance cardiograms.使用总体平均阻抗心动图测定心输出量。
J Appl Physiol (1985). 1985 Jan;58(1):200-5. doi: 10.1152/jappl.1985.58.1.200.
3
A comparison between cardiac output determined by impedance cardiography and the rebreathing method during exercise in man.人体运动期间通过阻抗心动描记法与重复呼吸法测定的心输出量比较。
Jpn J Physiol. 1989;39(3):441-6. doi: 10.2170/jjphysiol.39.441.
4
The lowering of stroke volume measured by means of impedance cardiography during endexpiratory breath holding.呼气末屏气期间通过阻抗心动描记法测量的每搏输出量降低。
Physiol Meas. 1996 Feb;17(1):29-35. doi: 10.1088/0967-3334/17/1/003.
5
Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.
Clin Sci (Lond). 1982 Aug;63(2):107-13. doi: 10.1042/cs0630107.
6
Comparison of cardiac output during exercise by single-breath and CO2-rebreathing methods.
J Appl Physiol (1985). 1985 Apr;58(4):1372-7. doi: 10.1152/jappl.1985.58.4.1372.
7
Comparison of two noninvasive techniques for estimating cardiac output during exercise.两种用于估计运动期间心输出量的非侵入性技术的比较。
J Appl Physiol (1985). 1986 Jul;61(1):155-9. doi: 10.1152/jappl.1986.61.1.155.
8
Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.心输出量的自动无创测量:电阻抗与二氧化碳重呼吸技术的比较
Br Heart J. 1988 Mar;59(3):292-8. doi: 10.1136/hrt.59.3.292.
9
Cardiac output measured by electric bioimpedance compared with the CO2 rebreathing technique at different exercise levels.
Clin Physiol. 2000 Mar;20(2):101-5. doi: 10.1046/j.1365-2281.2000.00233.x.
10
Measurement of cardiac output by CO2 rebreathing in unsteady state exercise.非稳态运动中通过二氧化碳重呼吸法测量心输出量。
Chest. 1987 Nov;92(5):777-82. doi: 10.1378/chest.92.5.777.

引用本文的文献

1
Process techniques for human thoracic electrical bio-impedance signal in remote healthcare systems.远程医疗系统中人体胸部电阻抗生物电信号的处理技术
Healthc Technol Lett. 2016 Jun 13;3(2):124-8. doi: 10.1049/htl.2015.0061. eCollection 2016 Jun.
2
Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: Novel techniques and new advances.递增至最大有氧运动期间心输出量测量方法的可靠性和有效性。第二部分:新技术与新进展。
Sports Med. 1999 Apr;27(4):241-60. doi: 10.2165/00007256-199927040-00004.
3
Stroke volume measurement during supine and upright cycle exercise by impedance cardiography.
通过阻抗心动图测量仰卧位和直立位周期性运动期间的每搏输出量。
Ann Biomed Eng. 1994 Sep-Oct;22(5):514-23. doi: 10.1007/BF02367087.
4
Cardiovascular and sympatho-adrenal responses to static handgrip performed with one and two hands.单手和双手进行静态握力时的心血管及交感 - 肾上腺反应。
Eur J Appl Physiol Occup Physiol. 1989;59(3):184-8. doi: 10.1007/BF02386185.
5
Kinetics of cardiorespiratory response to dynamic and rhythmic-static exercise in men.男性对动态和节律性静态运动的心肺反应动力学
Eur J Appl Physiol Occup Physiol. 1990;61(3-4):230-6. doi: 10.1007/BF00357605.
6
Respiratory effects on cardiac related impedance indices measured under voluntary cardio-respiratory synchronisation (VCRS).在自主心肺同步(VCRS)下测量的呼吸对心脏相关阻抗指数的影响。
Med Biol Eng Comput. 1991 Sep;29(5):505-10. doi: 10.1007/BF02442322.
7
Cardiac output, oxygen consumption and arteriovenous oxygen difference following a sudden rise in exercise level in humans.人体运动强度突然增加后的心输出量、氧耗量和动静脉氧差。
J Physiol. 1991 Sep;441:501-12. doi: 10.1113/jphysiol.1991.sp018764.