OBJECTIVES

A new device that combines, for the first time, two photonic technologies (time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy) was provided and tested within the BabyLux project. Aim was to validate the expected changes in cerebral oxygenation and blood flow.

METHODS

A pulse oximeter and the BabyLux device were held in place (right hand/wrist and frontoparietal region, respectively) for 10 min after birth in healthy term infants delivered by elective caesarean section. Pulse oximeter saturation (SpO), cerebral tissue oxygen saturation (StO) and blood flow index (BFI) were measured over time. Tissue oxygen extraction (TOE) and cerebral metabolic rate of oxygen index (CMROI) were calculated.

RESULTS

Thirty infants were enrolled in two centres. After validity check of data, 23% of infants were excluded from TOE and CMROI calculation due to missing data. As expected, SpO (estimate 3.05 %/min; 95% CI 2.78 to 3.31 %/min) and StO (estimate 3.95 %/min; 95% CI 3.63 to 4.27 %/min) increased in the first 10 min after birth, whereas BFI (estimate -2.84×10 cm/s/min; 95% CI -2.50×10 to -3.24×10 cm/s/min) and TOE (estimate -0.78 %/min; 95% CI -1.12 to -0.45 %/min) decreased. Surprisingly, CMROI decreased (estimate -7.94×10/min; 95% CI -6.26×10 to -9.62×10/min).

CONCLUSIONS

Brain oxygenation and BFI during transition were successfully and simultaneously obtained by the BabyLux device; no adverse effects were recorded, and the BabyLux device did not limit the standard care. The preliminary results from clinical application of the BabyLux device are encouraging in terms of safety and feasibility; they are consistent with previous reports on brain oxygenation during transition, although the interpretation of the decreasing CMROI remains open.

TRIAL REGISTRATION NUMBER

NCT02815618.

摘要

目的

婴儿 lux 项目首次提供并测试了一种将两种光子技术(时间分辨近红外光谱和漫反射相关光谱)结合在一起的新设备。目的是验证脑氧合和血流的预期变化。

方法

在选择性剖宫产分娩的健康足月婴儿出生后 10 分钟内,将脉搏血氧仪和婴儿 lux 设备分别放置在右手/手腕和额顶区域。随着时间的推移,测量脉搏血氧饱和度(SpO)、脑组织氧饱和度(StO)和血流指数(BFI)。计算组织氧提取(TOE)和脑氧代谢指数(CMROI)。

结果

在两个中心共纳入 30 名婴儿。在对数据进行有效性检查后,由于数据缺失,23%的婴儿被排除在 TOE 和 CMROI 计算之外。正如预期的那样,出生后 10 分钟内 SpO(估计值为 3.05%/min;95%CI 为 2.78%至 3.31%/min)和 StO(估计值为 3.95%/min;95%CI 为 3.63%至 4.27%/min)增加,而 BFI(估计值为-2.84×10 cm/s/min;95%CI 为-2.50×10 至-3.24×10 cm/s/min)和 TOE(估计值为-0.78%/min;95%CI 为-1.12%至-0.45%/min)降低。令人惊讶的是,CMROI 降低(估计值为-7.94×10/min;95%CI 为-6.26×10 至-9.62×10/min)。

结论

婴儿 lux 设备成功且同时获得了过渡期间的脑氧合和 BFI;未记录到不良反应,婴儿 lux 设备并未限制标准护理。婴儿 lux 设备在安全性和可行性方面的临床应用初步结果令人鼓舞;它们与过渡期间脑氧合的先前报告一致,尽管对 CMROI 降低的解释仍存在争议。

试验注册号

NCT02815618。