日本放射治疗中使用形变图像配准软件的临床应用实况调查。

Factual survey of the clinical use of deformable image registration software for radiotherapy in Japan.

机构信息

Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.

Department of Radiotherapy, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, Japan.

出版信息

J Radiat Res. 2019 Jul 1;60(4):546-553. doi: 10.1093/jrr/rrz034.

Abstract

Deformable image registration (DIR) has recently become commercially available in the field of radiotherapy. However, there was no detailed information regarding the use of DIR software at each medical institution. Thus, in this study, we surveyed the status of the clinical use of DIR software for radiotherapy in Japan. The Japan Society of Medical Physics and the Japanese Society for Radiation Oncology mailing lists were used to announce this survey. The questionnaire was created by investigators working under the research grant of the Japanese Society for Radiation Oncology (2017-2018) and intended for the collection of information regarding the use of DIR in radiotherapy. The survey was completed by 161 institutions in Japan. The survey results showed that dose accumulation was the most frequent purpose for which DIR was used in clinical practice (73%). Various commissioning methods were performed, although they were not standardized. Qualitative evaluation with actual patient images was the most commonly used method (28%), although 30% of the total number of responses (42% of institutions) reported that they do not perform commissioning. We surveyed the current status of clinical use of DIR software for radiotherapy in Japan for the first time. Our results indicated that a certain number of institutions used DIR software for clinical practice, and various commissioning methods were performed, although they were not standardized. Taken together, these findings highlight the need for a technically unified approach for commissioning and quality assurance for the use of DIR software in Japan.

摘要

形变图像配准(DIR)最近已在放射治疗领域商业化。然而,各医疗机构使用 DIR 软件的详细信息并不清楚。因此,本研究对日本放射治疗中 DIR 软件的临床应用状况进行了调查。该调查通过日本医学物理学会和日本放射肿瘤学会的邮件列表发布。问卷由日本放射肿瘤学会(2017-2018 年)资助的研究人员创建,旨在收集放射治疗中 DIR 使用的信息。该调查完成于日本的 161 个机构。调查结果表明,剂量累加是 DIR 在临床实践中最常使用的目的(73%)。尽管没有标准化,但已采用了各种调试方法。使用实际患者图像进行定性评估是最常用的方法(28%),尽管总回复数的 30%(42%的机构)表示他们不进行调试。这是我们首次对日本放射治疗中 DIR 软件的临床应用现状进行调查。我们的结果表明,一定数量的机构在临床实践中使用 DIR 软件,并采用了各种调试方法,尽管没有标准化。综上所述,这些发现强调了在日本需要采用技术统一的方法来调试和保证 DIR 软件的使用质量。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/97c7/6640912/0b7637b6fab9/rrz034f01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验