Suppr超能文献

数字化测量牙龈退缩与传统方法的准确性和可靠性。

The accuracy and reliability of digital measurements of gingival recession versus conventional methods.

机构信息

Division of Periodontics, College of Dentistry, Jazan University, P.O.Box 114, Jazan, 45142, Saudi Arabia.

出版信息

BMC Oral Health. 2019 Jul 16;19(1):154. doi: 10.1186/s12903-019-0851-0.

Abstract

BACKGROUND

An apical shift in the position of the gingiva beyond the cemento-enamel junction leads to gingival recession. This study aimed to evaluate the reproducibility of digital measurements of gingival recession when compared to conventional measurements taken clinically using periodontal probes.

METHODS

Gingival recession was measured at 97 sites in the oral cavity by four examiners using the following methods: CP, direct measurement of gingival recession using William's periodontal probe intraorally; CC, measurements on cast models using a caliper; DP, digital measurement on virtual models obtained by intraoral scanning, and DC, digital measurements on virtual models of dental casts. Intra-class and inter-rater correlations were analyzed. Bland Altman plots were drawn to visually determine the magnitude of differences in any given pair-wise measurements.

RESULTS

In this study, good inter-methods reliability was observed for almost all the examiners ranging from 0.907 to 0.918, except for one examiner (0.837). The greatest disagreements between the raters were observed for methods; CP (0.631) followed by CC (0.85), while the best agreements were observed for methods DP (0.9) followed by DC (0.872).

CONCLUSION

Variations in measurements between examiners can be reduced by using digital technologies when compared to conventional methods. Improved reproducibility of measurements obtained via intraoral scanning will increase the validity and reliability of future studies that compare different treatment modalities for root coverage.

摘要

背景

牙龈位置向牙釉质-牙骨质界上方的牙槽嵴顶方向移动会导致牙龈退缩。本研究旨在评估与临床使用牙周探针进行的传统测量相比,数字化测量牙龈退缩的重现性。

方法

4 位检查者使用以下方法在口腔的 97 个部位测量牙龈退缩:CP,使用威廉牙周探针进行的口腔内直接测量牙龈退缩;CC,在石膏模型上使用卡尺进行的测量;DP,通过口腔内扫描获得的虚拟模型上的数字测量,以及 DC,在牙石膏模型的虚拟模型上的数字测量。分析了组内和组间的相关性。Bland-Altman 图用于直观地确定任何特定的两两测量之间差异的大小。

结果

在这项研究中,除了一位检查者(0.837)外,几乎所有检查者的所有方法之间都观察到了良好的方法间可靠性,范围从 0.907 到 0.918。检查者之间最大的分歧是 CP(0.631)和 CC(0.85),而 DP(0.9)和 DC(0.872)之间的一致性最好。

结论

与传统方法相比,使用数字技术可以减少检查者之间的测量差异。通过口腔内扫描获得的测量值的重现性提高,将提高未来比较不同根覆盖治疗方法的研究的有效性和可靠性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/73d5/6636111/d880315351f4/12903_2019_851_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验