Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul 138-736, Republic of Korea.
Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-Gil, Songpa-Gu, Seoul 138-736, Republic of Korea.
Clin Radiol. 2019 Oct;74(10):817.e9-817.e14. doi: 10.1016/j.crad.2019.06.023. Epub 2019 Jul 27.
To retrospectively compare sensitivity encoding (SENSE) and compressed sensing-sensitivity encoding (CS-SENSE) for high resolution (HR) cranial nerve magnetic resonance imaging (MRI) in a clinical population.
Twenty consecutive patients who were clinically suspected of neurovascular compression syndrome (NVCS) were enrolled in this study. HR three-dimensional isotropic T2-weighted fast spin-echo (T2 VISTA) sequences with SENSE or CS-SENSE, and contrast-enhanced three-dimensional T1-turbo field-echo (CE 3D T1 TFE) with SENSE or CS-SENSE, were compared using quantitative and qualitative methods by two board-certified neuroradiologists.
For the T2 VISTA, CS-SENSE was significantly superior to SENSE in terms of cerebrospinal fluid homogeneity. For CE 3D T1 TFE, CS-SENSE was significantly superior to SENSE in terms of the existence of ghost artefact and the signal-to-noise ratio (SNR) of the pontine parenchyma. There was no significant difference in overall image quality between the two techniques. Compared with SENSE, CS-SENSE reduced the scan time to 44.2% of that with SENSE on T2 VISTA, and to 66.1% of that with SENSE of the CE 3D T1 TFE, with the differences being statistically significant (p<0.01, both).
For T2 VISTA and CE 3D T1 TFE imaging of patients with suspected NVCS, CS-SENSE appears to offer superior reductions in motion artefact and scan time relative to SENSE, without a loss of overall image quality.
回顾性比较敏感编码(SENSE)和压缩感知敏感编码(CS-SENSE)在临床人群高分辨率(HR)颅神经磁共振成像(MRI)中的应用。
本研究纳入了 20 例临床怀疑为神经血管压迫综合征(NVCS)的连续患者。采用 SENSE 或 CS-SENSE 的 HR 三维各向同性 T2 加权快速自旋回波(T2 VISTA)序列和 SENSE 或 CS-SENSE 的对比增强三维 T1 涡轮场回波(CE 3D T1 TFE)序列,由两位经过董事会认证的神经放射科医生使用定量和定性方法进行比较。
对于 T2 VISTA,CS-SENSE 在脑脊液均匀性方面明显优于 SENSE。对于 CE 3D T1 TFE,CS-SENSE 在鬼影的存在和桥脑实质的信噪比(SNR)方面明显优于 SENSE。两种技术的总体图像质量无显著差异。与 SENSE 相比,CS-SENSE 将 T2 VISTA 的扫描时间缩短至 SENSE 的 44.2%,将 CE 3D T1 TFE 的扫描时间缩短至 SENSE 的 66.1%,差异具有统计学意义(p<0.01,均)。
对于怀疑 NVCS 的患者的 T2 VISTA 和 CE 3D T1 TFE 成像,CS-SENSE 似乎可以在不降低整体图像质量的情况下,比 SENSE 更有效地减少运动伪影和扫描时间。