Suppr超能文献

角膜生物力学指标与圆锥角膜严重程度的相关性。

Correlation Between Corneal Biomechanical Indices and the Severity of Keratoconus.

机构信息

Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan.

Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan.

出版信息

Cornea. 2020 Feb;39(2):215-221. doi: 10.1097/ICO.0000000000002129.

Abstract

PURPOSE

To investigate the correlations between the biomechanical indices determined in Scheimpflug-based corneal biomechanical assessments and the severity of keratoconus (KC) based on corneal tomographic assessments in patients with different stages of KC.

METHODS

Fifty-three patients who presented with clinical KC in 1 eye and KC suspect in the fellow eye were included. Corneal tomographic and biomechanical assessments were performed using the Pentacam HR and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). Correlations between the tomographic indices and biomechanical indices were assessed, including the anterior radius of curvature (ARC) and posterior radius of curvature (PRC) at a 3.0-mm optical zone and the thinnest pachymetry (Tmin), deformation amplitude ratio max 2 mm (DAR2mm), integrated radius, stiffness parameter at the first applanation, and linear Corvis Biomechanical Index (beta).

RESULTS

DAR2mm correlated negatively with ARC (R = -0.722), PRC (R = -0.677), and Tmin (R= -0.650) (P < 0.001 for all). Integrated radius correlated negatively with ARC (R = -0.700), PRC (R = -0.668), and Tmin (R= -0.648) (P < 0.001 for all). Stiffness parameter at the first applanation correlated positively with ARC (R = 0.622), PRC (R = 0.601), and Tmin (R = 0.703) (P < 0.001 for all). The Corvis Biomechanical Index beta correlated negatively with ARC (R = -0.754), PRC (R = -0.755), and Tmin (R= -0.765) (P < 0.001 for all).

CONCLUSIONS

Corneal biomechanical indices correlated with corneal tomographic parameters in patients with KC. These findings support the possibility of developing biomechanical-based staging classification for KC in combination with topographic or tomographic indices.

摘要

目的

研究基于 Scheimpflug 的角膜生物力学评估中确定的生物力学指标与不同阶段圆锥角膜(KC)患者基于角膜断层评估的 KC 严重程度之间的相关性。

方法

纳入了 53 例单眼临床 KC 和对侧眼 KC 疑似患者。使用 Pentacam HR 和 Corvis ST(Oculus Optikgeräte GmbH,德国威茨拉尔)进行角膜断层和生物力学评估。评估了断层参数与生物力学参数之间的相关性,包括 3.0mm 光区的前曲率半径(ARC)和后曲率半径(PRC)以及最薄角膜厚度(Tmin)、最大 2mm 变形幅度比(DAR2mm)、整合半径、第一次压平的刚性参数和线性 Corvis 生物力学指数(beta)。

结果

DAR2mm 与 ARC(R=-0.722)、PRC(R=-0.677)和 Tmin(R=-0.650)呈负相关(P<0.001)。整合半径与 ARC(R=-0.700)、PRC(R=-0.668)和 Tmin(R=-0.648)呈负相关(P<0.001)。第一次压平的刚性参数与 ARC(R=0.622)、PRC(R=0.601)和 Tmin(R=0.703)呈正相关(P<0.001)。Corvis 生物力学指数 beta 与 ARC(R=-0.754)、PRC(R=-0.755)和 Tmin(R=-0.765)呈负相关(P<0.001)。

结论

KC 患者的角膜生物力学指标与角膜断层参数相关。这些发现支持在结合拓扑或断层参数的情况下,为 KC 开发基于生物力学的分期分类的可能性。