Department of Radiology, C.J. Gorter Center for High Field MRI, Leiden University Medical Center, Leiden, The Netherlands.
Center for Image Sciences, University Medical Centre Utrecht, Utrecht, The Netherlands.
Magn Reson Med. 2020 Mar;83(3):872-882. doi: 10.1002/mrm.27973. Epub 2019 Sep 4.
In this study, the influence of the cardiac cycle on the amount of label produced by a velocity-selective (VSASL) and acceleration-selective arterial spin labeling (AccASL) module was investigated.
A short-PLD sequence was developed where a single VSASL- or AccASL-module was preceded by pCASL labeling to isolate the arterial blood pool. ASL subtraction was performed with label/control images with similar cardiac phase and time-of-measurement, followed by retrospective binning in 10 cardiac phase bins. ASL signal variation over the heart cycle was evaluated and tested for significance using a permutation test.
VSASL and AccASL showed significant arterial signal fluctuations over the cardiac cycle of up to ~36% and ~64%, respectively, mainly in areas containing large arteries. pCASL also showed significant signal fluctuations, of up to ~25% in arteries. Raw label/control images confirmed that the observed signal fluctuations were caused by the amount of label produced during the cardiac cycle, rather than inflow-effects, because the raw images did not all show equal cardiac phase dependence. No significant effects of the cardiac cycle were found on the gray matter ASL-signal.
Significant influence of the cardiac cycle on the generated label was found for spatially nonselective ASL-sequences. Hence, to become independent of the cardiac cycle, sufficient averages need to be taken. Alternatively, these findings could be highly interesting for the purpose of quantifying pulsatility more distally in the vascular tree.
在本研究中,研究了心动周期对速度选择(VSASL)和加速度选择动脉自旋标记(AccASL)模块产生的标记量的影响。
开发了一种短 PLD 序列,其中单个 VSASL 或 AccASL 模块之前有 pCASL 标记,以分离动脉血池。使用具有相似心脏相位和测量时间的标记/对照图像进行 ASL 减法,然后在 10 个心脏相位 bin 中进行回顾性 binning。评估 ASL 信号在心动周期中的变化,并使用置换检验测试其显著性。
VSASL 和 AccASL 在心动周期中显示出显著的动脉信号波动,幅度高达约 36%和 64%,主要在包含大动脉的区域。pCASL 也显示出显著的信号波动,幅度高达约 25%的动脉。原始标记/对照图像证实,观察到的信号波动是由心动周期中产生的标记量引起的,而不是流入效应,因为原始图像并不都显示出相等的心脏相位依赖性。未发现心动周期对灰质 ASL 信号有显著影响。
对于非空间选择性 ASL 序列,发现心动周期对产生的标记有显著影响。因此,为了使其不受心动周期的影响,需要进行足够的平均处理。或者,这些发现对于在血管树的更远部位更准确地量化脉动性可能非常有趣。