Use of transthoracic bioimpedance to determine cardiac output in pediatric patients.

作者信息

Introna R P, Pruett J K, Crumrine R C, Cuadrado A R

机构信息

Department of Anesthesiology, School of Medicine, Medical College of Georgia, Augusta 30912.

出版信息

Crit Care Med. 1988 Nov;16(11):1101-5. doi: 10.1097/00003246-198811000-00004.

Abstract

The use of a transthoracic bioimpedance monitor to determine cardiac output was evaluated in critically ill children. The children ranged in age from 10 months to 8 yr and their height and weight ranged from the third to the 97th percentile. Each child had a thermodilution catheter in place to monitor cardiac output. The bioimpedance monitor used in this study, the NCCOM-3, required the input of a constant (L), which was obtained for each individual patient by adjusting the L setting until cardiac output measured by bioimpedance (COBI) was within 10% of cardiac output measured by thermodilution (COTD). This method of determining L was superior to using either measured thoracic length or the manufacturer's guidelines to obtain L and resulted in an excellent correlation between COTD and COBI (r = .94; p less than .05; n = 59). In children less than 125 cm in height, measured thoracic length alone was inadequate to use for L but provided a good approximation of L when multiplied by 1.25. This study suggests that the use of transthoracic bioimpedance to determine cardiac output compares favorably with thermodilution techniques and it is noninvasive.