Chu C S, McManus A T, Pruitt B A, Mason A D
U.S. Army Institute of Surgical Research, Fort Sam Houston, San Antonio, TX 78234-6200.
J Trauma. 1988 Oct;28(10):1488-92. doi: 10.1097/00005373-198810000-00016.
The therapeutic and prophylactic effects of nylon dressings coated with metallic silver in a direct current circuit have been examined in a rat model of fatal burn wound sepsis. Male Sprague-Dawley rats weighing 325 +/- 25 grams with 20% full-thickness scald injuries were used. Therapeutic effects were examined at 4 or 24 hours after surface inoculation with a lethal dose of Pseudomonas aeruginosa (Strain 59-1244). When used as a surface anode with an implanted silver needle cathode, the silver nylon was therapeutic at currents between 0.4 and 40 microA when applied at either test time and continued for 5 days (p less than 0.001). When used as a cathode, silver nylon was not effective. Nylon cloth without a silver metal coating was not effective without applied current or when used as an anode. Silver nylon dressings placed at 4 hours after inoculation but without applied current showed significant effectiveness (p less than 0.01). This effect, however, was significantly less than that seen with silver nylon used as an anode (p less than 0.001). Barrier prophylactic effects were examined by placing silver nylon or uncoated nylon on burn wounds before inoculation with Pseudomonas aeruginosa. The uncoated nylon had no barrier effect. Silver nylon was found protective but applied current was not required for significant (p less than 0.001) barrier effect. These results indicate silver nylon dressings may be a valuable antimicrobial burn wound covering device.
在致命性烧伤创面脓毒症大鼠模型中,研究了直流电路中涂有金属银的尼龙敷料的治疗和预防作用。使用体重为325±25克、有20%全层烫伤的雄性Sprague-Dawley大鼠。在表面接种致死剂量的铜绿假单胞菌(菌株59-1244)后4小时或24小时检查治疗效果。当用作表面阳极并带有植入的银针阴极时,银尼龙在0.4至40微安的电流下于任一测试时间应用并持续5天具有治疗作用(p<0.001)。当用作阴极时,银尼龙无效。没有银金属涂层的尼龙布在未施加电流或用作阳极时无效。接种后4小时放置但未施加电流的银尼龙敷料显示出显著效果(p<0.01)。然而,这种效果明显小于用作阳极的银尼龙(p<0.001)。通过在接种铜绿假单胞菌之前将银尼龙或未涂层尼龙放置在烧伤创面上检查屏障预防作用。未涂层尼龙没有屏障作用。发现银尼龙具有保护作用,但显著的(p<0.001)屏障作用不需要施加电流。这些结果表明银尼龙敷料可能是一种有价值的抗菌烧伤创面覆盖装置。