Suppr超能文献

瑞士成人 CT 国家诊断参考水平更新及 2010 年以来放射剂量降低评估。

Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010.

机构信息

Department of Radiology, University Hospital Basel, University of Basel, Petersgraben 4, 4031, Basel, Switzerland.

Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland.

出版信息

Eur Radiol. 2020 Mar;30(3):1690-1700. doi: 10.1007/s00330-019-06485-1. Epub 2019 Nov 20.

Abstract

OBJECTIVES

To update the national diagnostic reference levels (DRLs) for adult CT in Switzerland using dose management software and to compare them to the previous Swiss DRLs from 2010.

METHODS

CT dose data from 14 radiological institutes with a total of 50 CT scanners were collected with locally installed dose management software between 2014 and 2017. Data were assigned to 15 defined master protocols. Data cleaning steps were developed and adjusted individually for each participating institute and protocol. The DRLs for each master protocol were calculated as the 75th percentile of the distribution of the median volume computed tomography dose index (CTDI) and dose-length product (DLP) values per CT scanner.

RESULTS

In total, 220,269 CT exams were available after data cleaning. Updated DRLs showed a clear trend towards lower doses compared with previous DRLs. The average relative change in the DRLs for CTDI was - 30% (0 to - 47%) and - 22% for DLP (+ 20 to - 40%). The largest relative decrease in the DRL for DLP was observed for the cervical spine protocol (- 40%), the two chest protocols (chest, - 37%; and exclusion of pulmonary embolism, - 33%), and the two neck protocols (neck, - 32%; and carotid angiography, - 28%). The DRLs for other protocols, for example the head and the abdomen-pelvis protocol, showed smaller relative changes (- 11% and - 17%).

CONCLUSIONS

The updated national DRLs are substantially lower than the previous values from 2010, demonstrating technological progress and the efforts of the radiological community to lower CT radiation exposure.

KEY POINTS

• Dose management software allows the establishment of DRLs based on big data. • Updated Swiss DRLs for adult CT are substantially lower compared with those from 2010. • Swiss DRLs are low compared with other national DRLs.

摘要

目的

使用剂量管理软件更新瑞士成人 CT 的国家诊断参考水平(DRLs),并将其与 2010 年的瑞士先前 DRL 进行比较。

方法

2014 年至 2017 年间,使用本地安装的剂量管理软件从 14 个放射学研究所的 50 台 CT 扫描仪中收集 CT 剂量数据。数据被分配到 15 个定义明确的主协议中。为每个参与的研究所和协议单独开发和调整了数据清理步骤。每个主协议的 DRL 计算为每个 CT 扫描仪的体积 CT 剂量指数(CTDI)和剂量长度乘积(DLP)值中位数分布的第 75 个百分位数。

结果

经过数据清理后,共获得 220,269 次 CT 检查。与先前的 DRL 相比,更新后的 DRL 显示出明显的剂量降低趋势。CTDI 的 DRL 平均相对变化为-30%(0 至-47%),DLP 的 DRL 为-22%(+20 至-40%)。DLP 的 DRL 最大相对降低见于颈椎方案(-40%)、两个胸部方案(胸部,-37%;排除肺栓塞,-33%)和两个颈部方案(颈部,-32%;颈动脉血管造影,-28%)。其他方案的 DRL,例如头部和腹部-骨盆方案,显示出较小的相对变化(-11%和-17%)。

结论

更新后的国家 DRL 远低于 2010 年的先前值,证明了技术进步和放射学社区降低 CT 辐射暴露的努力。

关键点

• 剂量管理软件允许基于大数据建立 DRL。

• 与 2010 年相比,瑞士成人 CT 的更新 DRL 大幅降低。

• 与其他国家的 DRL 相比,瑞士的 DRL 较低。