Imaging assessment of the anterior visual pathway structures, particularly the optic nerves (ON), requires knowledge of normal dimensions. Several studies suggesting techniques and normal ranges have been performed, but most suffer from various methodological flaws. This study is the first to be performed in a South African population.
The aim of this study was to establish normal measurements of the ON, optic nerve sheath (ONS) and optic chiasm (OC) on magnetic resonance imaging (MRI).
Eighty normal adults between ages of 12 and 65 years were included in this prospective, quantitative, observational, descriptive study to establish normal measurement of the ON, ONS and OC using a T2W 3D MRI sequence. Measurements (width and height) were undertaken by two observers independently.
A total of 80 participants with a mean age of 35 years were studied: 49 females (61.25%) and 31 males (38.75%). There were no statistical differences in the measurements between gender and age correlation. Interobserver agreement was best for larger structures, that is, OC width and intracranial ON width, respectively. The overall mean of OC width was 13.63 mm (range: 11.13 mm-16.92 mm, standard deviation [s.d.] 1.21); intraorbital ON height at 5 mm behind the globe 2.29 mm (range: 1.63 mm-3.33 mm, s.d. 0.43), and intracranial ON width 4.27 mm (range: 2.46 mm-5.19 mm, s.d. 0.53).
Normal measurements of the anterior visual pathway structures on MRI are best reflected in the larger structures. Interobserver variability was poor for the orbital ON, ONS, intracranial ON height and OC height. We recommend that measurements be obtained for the OC width and intracranial ON width. The overall mean for the OC width is 13.63 mm and intracranial ON width 4.27 mm.
对前视觉通路结构,尤其是视神经(ON)进行影像学评估,需要了解其正常尺寸。已有多项研究提出了相关技术和正常范围,但大多数研究存在各种方法学缺陷。本研究是首次在南非人群中开展的此类研究。
本研究旨在通过磁共振成像(MRI)确定视神经、视神经鞘(ONS)和视交叉(OC)的正常测量值。
本前瞻性、定量、观察性、描述性研究纳入了80名年龄在12至65岁之间的正常成年人,使用T2W 3D MRI序列确定视神经、视神经鞘和视交叉的正常测量值。测量(宽度和高度)由两名观察者独立进行。
共研究了80名参与者,平均年龄为35岁:49名女性(61.25%)和31名男性(38.75%)。性别和年龄相关性测量结果无统计学差异。观察者间一致性在较大结构(即视交叉宽度和颅内段视神经宽度)方面最佳。视交叉宽度的总体平均值为13.63毫米(范围:11.13毫米至16.92毫米,标准差[s.d.]1.21);眼球后5毫米处眶内段视神经高度为2.29毫米(范围:1.63毫米至3.33毫米,s.d.0.43),颅内段视神经宽度为4.27毫米(范围:2.46毫米至5.19毫米,s.d.0.53)。
MRI上前视觉通路结构的正常测量值在较大结构中体现得最为明显。眶内段视神经、视神经鞘、颅内段视神经高度和视交叉高度的观察者间变异性较差。我们建议对视交叉宽度和颅内段视神经宽度进行测量。视交叉宽度的总体平均值为13.63毫米,颅内段视神经宽度为4.27毫米。