Suppr超能文献

使用光学相干弹性成像技术监测血液稀释凝血过程中的粘度

Viscosity monitoring during hemodiluted blood coagulation using optical coherence elastography.

作者信息

Xu Xiangqun, Zhu Jiang, Yu Junxiao, Chen Zhongping

机构信息

College of Life Sciences, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, China, and the Beckman Laser Institute, University of California, Irvine, Irvine, California 92612, USA.

Beckman Laser Institute, University of California, Irvine, Irvine, California 92612, USA.

出版信息

IEEE J Sel Top Quantum Electron. 2019 Jan-Feb;25(1). doi: 10.1109/JSTQE.2018.2833455. Epub 2018 May 7.

Abstract

Rapid and accurate clot diagnostic systems are needed for the assessment of hemodiluted blood coagulation. We develop a real-time optical coherence elastography (OCE) system, which measures the attenuation coefficient of a compressional wave induced by a piezoelectric transducer (PZT) in a drop of blood using optical coherence tomography (OCT), for the determination of viscous properties during the dynamic whole blood coagulation process. Changes in the viscous properties increase the attenuation coefficient of the sample. Consequently, dynamic blood coagulation status can be monitored by relating changes of the attenuation coefficient to clinically relevant coagulation metrics, including the initial coagulation time and the clot formation rate. This system was used to characterize the influence of activator kaolin and the influence of hemodilution with either NaCl 0.9% or hydroxyethyl starch (HES) 6% on blood coagulation. The results show that PZT-OCE is sensitive to coagulation abnormalities and is able to characterize blood coagulation status based on viscosity-related attenuation coefficient measurements. PZT-OCE can be used for point-of-care testing for diagnosis of coagulation disorders and monitoring of therapies.

摘要

评估血液稀释后的凝血功能需要快速准确的凝血诊断系统。我们开发了一种实时光学相干弹性成像(OCE)系统,该系统使用光学相干断层扫描(OCT)测量压电换能器(PZT)在一滴血液中诱导产生的压缩波的衰减系数,以确定动态全血凝血过程中的粘性特性。粘性特性的变化会增加样品的衰减系数。因此,通过将衰减系数的变化与临床相关的凝血指标(包括初始凝血时间和凝块形成率)相关联,可以监测动态凝血状态。该系统用于表征激活剂高岭土的影响以及0.9%氯化钠或6%羟乙基淀粉(HES)血液稀释对凝血的影响。结果表明,PZT-OCE对凝血异常敏感,并且能够基于与粘度相关的衰减系数测量来表征凝血状态。PZT-OCE可用于即时检测,以诊断凝血障碍和监测治疗效果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9d3a/6922089/7d85caae6b1f/nihms-975325-f0005.jpg

相似文献

4
Optical coherence elastography in ophthalmology.眼科光学相干弹性成像。
J Biomed Opt. 2017 Dec;22(12):1-28. doi: 10.1117/1.JBO.22.12.121720.

本文引用的文献

1
Design and implementation of a low-cost, portable OCT system.一种低成本便携式光学相干断层扫描(OCT)系统的设计与实现。
Biomed Opt Express. 2018 Feb 20;9(3):1232-1243. doi: 10.1364/BOE.9.001232. eCollection 2018 Mar 1.
9
Acoustic Radiation Force Optical Coherence Elastography of Corneal Tissue.角膜组织的声辐射力光学相干弹性成像
IEEE J Sel Top Quantum Electron. 2016 May-Jun;22(3). doi: 10.1109/JSTQE.2016.2524618. Epub 2016 Feb 8.