Am J Ophthalmol. 2020 Jun;214:72-85. doi: 10.1016/j.ajo.2019.12.015. Epub 2019 Dec 25.
Limited information is available on morphologic and functional regeneration of photoreceptors after retinal detachment (RD) surgery. This observational clinical study compared morphologic and functional changes of cones after vitrectomy for macula-off retinal detachment.
Prospective, fellow-eye comparative case series.
StudyPopulation: Five eyes after vitrectomy with gas for macula-off retinal detachment (retinal detachment eyes, RDE) and 5 healthy fellow eyes (HFE) of 5 patients (mean age 59.8 years, macula-off duration 0.5 days to 5.5 days). ObservationProcedures: Eyes were examined with adaptive-optics optical coherence tomography (AO-OCT), spectral-domain OCT (SDOCT), and microperimetry (MP) at 6 (baseline, BL) and 56 weeks (follow-up, FUP) after 23 gauge pars plana vitrectomy and SF6 gas tamponade. Eight corresponding regions at foveal eccentricities of 2.5° (ecc 2.5°) and 6.5° (ecc 6.5°) were analyzed in every eye. AO-OCT en face images and SD-OCT B-scans were graded regarding irregularity and loss of photoreceptor signals ranging from none to severe changes. The number of detectable cones at height of the inner-outer segment junction (IS/OS) and cone outer segment tips (COST) was counted manually in AO-OCT images. MP with a custom grid was used to assess retinal sensitivity at these locations. MainOutcomeMeasures: Cone density, cone pattern regularity and signal attenuation, retinal sensitivity.
In comparison to HFE, RDE showed highly irregular cone patterns in AO-OCT and irregular outer retinal bands in SDOCT. Despite significant improvement of cone pattern regularity compared to BL (P < .001), 63% of AO images showed remaining cone pattern irregularity and 45.5% of SDOCT B-scans showed severe signal reduction at FUP. In HFE, mean cone density retrieved from IS/OS and COST remained around 20,000/mm (ecc 2.5°) and 16,000/mm (ecc 6.5°) at BL and FUP. Cone density of RDE was significantly reduced and ranged between 200/mm and 15,600/mm (P < .001) at BL. Despite improvement at FUP (P < .001), mean cone density at IS/OS and COST was still lower compared to HFE and ranged between 7790 and 9555 cones/mm (P < .001). Mean retinal sensitivity of all measured locations remained 18 dB in HFE and was significantly lower in RDE, with 14.30 dB at BL and 14.64 dB at FUP. Both SDOCT grading and microperimetry sensitivity showed strong correlation with AO-OCT grading and cone density (rho values > 0.750).
The combination of AO-OCT, SDOCT, and microperimetry is a powerful tool to capture cone regeneration after vitreoretinal surgery. Our study shows that cone morphology and function improve within 56 weeks after RD surgery but structural and functional impairment is still present.
关于视网膜脱离(RD)手术后光感受器的形态和功能再生,目前仅有有限的信息。本观察性临床研究比较了黄斑裂孔视网膜脱离玻璃体切除术后的锥体形态和功能变化。
前瞻性、对侧眼比较病例系列。
研究人群:5 例患者的 5 只眼(平均年龄 59.8 岁,黄斑裂孔脱离时间 0.5-5.5 天)在黄斑裂孔视网膜脱离(视网膜脱离眼,RDE)后接受玻璃体切除术和气体治疗,以及 5 只健康对侧眼(HFE)。观察程序:使用自适应光学光学相干断层扫描(AO-OCT)、光谱域 OCT(SDOCT)和微视野计(MP)在 23G 经睫状体平坦部玻璃体切除术后和 SF6 气体填充后 6 周(基线,BL)和 56 周(随访,FUP)对所有眼进行检查。在每个眼的 2.5°(偏心 2.5°)和 6.5°(偏心 6.5°)的黄斑中心凹偏心处分析了 8 个相应区域。AO-OCT 共焦图像和 SD-OCT B 扫描根据光感受器信号的不规则性和丢失程度进行分级,范围从无到严重改变。手动在 AO-OCT 图像中计算内-外节交界处(IS/OS)和锥体外节尖端(COST)高度处可检测锥体的数量。使用定制网格的 MP 用于评估这些位置的视网膜敏感性。
锥体密度、锥体形态规则性和信号衰减、视网膜敏感性。
与 HFE 相比,RDE 在 AO-OCT 中表现出高度不规则的锥体模式,在 SDOCT 中表现出不规则的外视网膜带。尽管与 BL 相比(P <.001),锥体形态规则性有显著改善,但 63%的 AO 图像仍显示锥体形态不规则,45.5%的 SDOCT B 扫描显示在 FUP 时严重的信号减少。在 HFE 中,从 IS/OS 和 COST 恢复的平均锥体密度在 BL 和 FUP 时均保持在 20000/mm(偏心 2.5°)和 16000/mm(偏心 6.5°)左右。RDE 的锥体密度显著降低,BL 时范围为 200/mm 至 15600/mm(P <.001)。尽管在 FUP 时有所改善(P <.001),但 IS/OS 和 COST 的平均锥体密度仍低于 HFE,范围为 7790 至 9555 个/mm(P <.001)。所有测量位置的平均视网膜敏感性在 HFE 中保持 18dB,在 RDE 中显著降低,BL 时为 14.30dB,FUP 时为 14.64dB。SDOCT 分级和微视野计敏感性与 AO-OCT 分级和锥体密度均具有很强的相关性(rho 值>0.750)。
AO-OCT、SDOCT 和微视野计的组合是捕捉玻璃体视网膜手术后锥体再生的有力工具。我们的研究表明,RD 手术后 56 周内锥体形态和功能得到改善,但结构和功能仍有损伤。