Andreuccetti D, Bini M, Ignesti A, Olmi R, Rubino N, Vanni R
IROE, Consiglio Nazionale delle Ricerche, Firenze, Italy.
Bioelectromagnetics. 1988;9(4):373-9. doi: 10.1002/bem.2250090407.
Results are presented of an investigation on electric and magnetic fields leaking from inductive (magnetic) heaters that are used for thermal processing of high-power electron tubes and lasers in an industrial plant. Measurements of electric and magnetic fields were done using both commercially available and laboratory-developed instrumentation. Isotropic H-field sensors were developed to allow quantitative evaluation of high-intensity magnetic fields. Ten induction heaters with nominal A.C. power ranging from 2.5 kW to 15 kW and operating at frequencies between 300 kHz and 790 kHz were surveyed. Electric field strengths up to 8 kV/m and magnetic field strengths up to 20 A/m were measured.
本文给出了对某工业厂房中用于大功率电子管和激光器热处理的感应(磁)加热器泄漏的电场和磁场进行调查的结果。使用市售仪器和实验室开发的仪器进行了电场和磁场测量。开发了各向同性H场传感器,以便对高强度磁场进行定量评估。对十台标称交流功率在2.5千瓦至15千瓦之间、工作频率在300千赫至790千赫之间的感应加热器进行了检测。测量得到的电场强度高达8千伏/米,磁场强度高达20安/米。