Conover D L, Murray W E, Lary J M, Johnson P H
Bioelectromagnetics. 1986;7(1):83-90. doi: 10.1002/bem.2250070109.
We discuss initial magnetic field strength measurements made around radiofrequency (RF) induction heaters. These measurements were made with a monitor developed for the National Institute for Occupational Safety and Health (NIOSH) by the National Bureau of Standards (NBS). The monitor has a dynamic range of .01 to 10,000 A2/m2, a frequency range of 300 kHz to 100 MHz, an isotropic response (+/- .3 dB) with three mutally orthogonal loop antennas that have the ability to measure and display each of three orthogonal magnetic field components, a high probe burnout protection level of 20,000 A2/m2, and an accuracy of +/- 1.0 dB at 13 calibration frequencies. The portable survey monitor was used to measure the magnetic field strengths in the vicinity of 16 RF induction heaters. Typically these induction heaters are operated continuously for several hours. The maximum field strengths (without duty factor correction) ranged from 15 to 4,500 A2/m2 and were measured 5 to 51 cm from the loop applicators of the induction heaters. At locations commonly occupied by workers (ie, approximately 30 to 76 cm from heaters), the fields ranged from .01 to 300 A2/m2 (without duty factor correction).
我们讨论了在射频(RF)感应加热器周围进行的初始磁场强度测量。这些测量是使用美国国家标准局(NBS)为美国国家职业安全与健康研究所(NIOSH)开发的监测器进行的。该监测器的动态范围为0.01至10,000 A²/m²,频率范围为300 kHz至100 MHz,具有各向同性响应(±0.3 dB),配备三个相互正交的环形天线,能够测量和显示三个正交磁场分量中的每一个,具有20,000 A²/m²的高探头烧毁保护水平,并且在13个校准频率下的精度为±1.0 dB。便携式测量监测器用于测量16个射频感应加热器附近的磁场强度。通常,这些感应加热器会连续运行数小时。最大场强(未进行占空比校正)范围为15至4,500 A²/m²,是在距离感应加热器的环形施加器5至51厘米处测量的。在工人通常占据的位置(即距离加热器约30至76厘米处),场强范围为0.01至300 A²/m²(未进行占空比校正)。