Onal Ozkan, Gumus Irem, Ozdemirkan Aysun, Cicekci Faruk, Sarı Mehmet, Bayram Hasan Huseyin, Ciftci Cansu, Aslanlar Emine, Celik Jale Bengi
Department of Anesthesiology and Reanimation, Medical Faculty, Selcuk University, Konya, Turkey.
Wideochir Inne Tech Maloinwazyjne. 2019 Dec;14(4):486-494. doi: 10.5114/wiitm.2019.83610. Epub 2019 Mar 14.
A difficult airway is one of the main causes of morbidity and mortality in patients who undergo surgical interventions. Therefore, many devices and algorithms have been developed for the management of a difficult airway. However no study has been conducted comparing Frova catheter (FC) and a Bonfils fiberoscope (BF) to date.
To compare the effectiveness and success of two devices, a FC and BF, in difficult intubation cases.
Design: Single-centre randomized controlled trial in patients with difficult airways. The assignment order was created by unplanned number charts, and the assignment was hidden in closed covers, which were not unlocked until case permission had been provided. Setting: The trial was undertaken in a university hospital in Turkey. The primary analysis was based on 60 participants (n = 30, n = 30) with difficult intubation. The main outcomes were the success rates of placement of the tracheal tube in the trachea and the duration of the tracheal intubation process.
In the BF group, successful intubation was carried out in 25 of the 30 (83.3%) patients, whereas intubation was successful in 28 of the 30 patients (93.3%) in the FC group. Patients who could not be intubated with the first device were intubated with the other device. The mean duration of intubation was 109 (85-140) s in the BF group, whereas it was 38.8 (26-60) s in the FC group.
Both devices were successful in difficult intubation cases. However, given the shorter duration of intubation using the FC and its lower cost as compared with that of the BF, the FC can be considered superior to the BF in difficult intubation cases.
困难气道是接受外科手术患者发病和死亡的主要原因之一。因此,已开发出许多用于处理困难气道的设备和算法。然而,迄今为止尚未有研究对弗罗瓦导管(FC)和邦菲尔斯纤维喉镜(BF)进行比较。
比较FC和BF这两种设备在困难插管病例中的有效性和成功率。
设计:针对困难气道患者的单中心随机对照试验。分配顺序由非计划数字表确定,分配情况隐藏在封闭封套中,直至获得病例许可才打开。地点:该试验在土耳其的一家大学医院进行。主要分析基于60名困难插管参与者(n = 30,n = 30)。主要结局是气管导管置入气管的成功率和气管插管过程的持续时间。
在BF组中,30例患者中有25例(83.3%)成功插管,而在FC组中,30例患者中有28例(93.3%)成功插管。无法用第一种设备插管的患者用另一种设备进行了插管。BF组的平均插管持续时间为109(85 - 140)秒,而FC组为38.8(26 - 60)秒。
两种设备在困难插管病例中均取得成功。然而,鉴于FC插管持续时间较短且成本低于BF,在困难插管病例中可认为FC优于BF。