Alcantara Juan M A, Plaza-Florido Abel, Amaro-Gahete Francisco J, Acosta Francisco M, Migueles Jairo H, Molina-Garcia Pablo, Sacha Jerzy, Sanchez-Delgado Guillermo, Martinez-Tellez Borja
PROFITH "PROmoting FITness and Health Through Physical Activity" Research Group, Sport and Health University Research Institute (iMUDS), Department of Physical and Sports Education, Faculty of Sport Sciences, University of Granada, 18011 Granada, Spain.
EFFECTS-262 Research Group, Department of Physiology, School of Medicine, University of Granada, 18071 Granada, Spain.
J Clin Med. 2020 Jan 23;9(2):325. doi: 10.3390/jcm9020325.
Heart rate variability (HRV) is a non-invasive indicator of autonomic nervous system function. HRV recordings show artefacts due to technical and/or biological issues. The Kubios software is one of the most used software to process HRV recordings, offering different levels of threshold-based artefact correction (i.e., Kubios filters). The aim of the study was to analyze the impact of different Kubios filters on the quantification of HRV derived parameters from short-term recordings in three independent human cohorts. A total of 312 participants were included: 107 children with overweight/obesity (10.0 ± 1.1 years, 58% men), 132 young adults (22.2 ± 2.2 years, 33% men) and 73 middle-aged adults (53.6 ± 5.2 years, 48% men). HRV was assessed using a heart rate monitor during 10-15 min, and the Kubios software was used for HRV data processing using all the Kubios filters available (i.e., 6). Repeated-measures analysis of variance indicated significant differences in HRV derived parameters in the time-domain (all < 0.001) across the Kubios filters in all cohorts, moreover similar results were observed in the frequency-domain. When comparing two extreme Kubios filters, these statistical differences could be clinically relevant, e.g. more than 10 ms in the standard deviation of all normal R-R intervals (SDNN). In conclusion, the results of the present study suggest that the application of different Kubios filters had a significant impact on HRV derived parameters obtained from short-term recordings in both time and frequency-domains.
心率变异性(HRV)是自主神经系统功能的一种非侵入性指标。HRV记录会因技术和/或生物学问题而显示出伪迹。库比奥斯(Kubios)软件是处理HRV记录时最常用的软件之一,它提供了不同级别的基于阈值的伪迹校正(即库比奥斯滤波器)。本研究的目的是分析不同的库比奥斯滤波器对来自三个独立人类队列的短期记录中HRV衍生参数量化的影响。总共纳入了312名参与者:107名超重/肥胖儿童(10.0±1.1岁,58%为男性)、132名年轻成年人(22.2±2.2岁,33%为男性)和73名中年成年人(53.6±5.2岁,48%为男性)。在10 - 15分钟内使用心率监测仪评估HRV,并使用库比奥斯软件对所有可用的库比奥斯滤波器(即6种)进行HRV数据处理。重复测量方差分析表明,在所有队列中,时域内(所有P<0.001)的HRV衍生参数在不同库比奥斯滤波器之间存在显著差异,此外在频域中也观察到了类似结果。当比较两种极端的库比奥斯滤波器时,这些统计差异可能具有临床相关性,例如所有正常R - R间期标准差(SDNN)相差超过10毫秒。总之,本研究结果表明,不同库比奥斯滤波器的应用对从短期记录中获得的时域和频域HRV衍生参数均有显著影响。