Suppr超能文献

胸前双极导联:一种研究前壁急性心肌梗死的新方法。

Precordial bipolar leads: A new method to study anterior acute myocardial infarction.

作者信息

Mc Loughlin Mario J

机构信息

Fundación Centro Diagnóstico Nuclear, Av. Nazca 3449, C1417CVE Buenos Aires. Argentina.

出版信息

J Electrocardiol. 2020 Mar-Apr;59:45-64. doi: 10.1016/j.jelectrocard.2019.12.017. Epub 2020 Jan 5.

Abstract

INTRODUCTION

A new ECG method produces Precordial Bipolar Leads (PBL) generated by subtraction of measurements of Standard Precordial Unipolar Leads (SPUL). This procedure brings new information about time/amplitude mismatch among SPUL, presenting it as tracings and local VCG loops exploring the precordial left-to-right axis on the horizontal plane. In this study, results of V2-V1 bipolar precordial derivation V2-V1 (right to left) and its relationship with the anteroposterior axis are presented.

MATERIAL AND METHODS

Records of 37 patients and 15 controls from Physionet database were used to create new PBL and compare between V1 and V2 SPUL. So, bipolar V2-V1 was obtained by subtracting V1 measurements from V2, always having as positive the V2 SPUL and as negative V1. The algorithm used was subtracting, in every millisecond, the voltage recorded by the right electrode from the simultaneously recorded left electrode. Combination of SPUL and PBL can be presented as tracings or local loops, showing detailed information of the electric horizontal plane of the heart at retrosternal location. PBL V2-V1 reflects right ventricle and septal electric activity.

RESULTS

The new method is able to detect changes in vectors and differences of milliseconds between SPUL and presents new and important information about the right-to-left electric axis. Right ventricle and interventricular septum electric activity can be differentiate in anterior AMI and LBBB.

CONCLUSION

Time/amplitude mismatch between SPUL could be the source of abundant and new information about cardiac depolarization and repolarization. As data to obtain PBL and new loops are already obtained in any ECG device that records simultaneously 12 leads, the system can be added to ECG software algorithms without any additional cable or recording work.

摘要

引言

一种新的心电图方法可产生胸前双极导联(PBL),它是通过对标准胸前单极导联(SPUL)的测量值进行减法运算生成的。这一过程带来了关于SPUL之间时间/幅度不匹配的新信息,将其呈现为描记图和局部心向量环,用于探索水平面从胸前左侧到右侧的轴。在本研究中,展示了V2 - V1胸前双极导联推导(从右到左)的结果及其与前后轴的关系。

材料与方法

使用来自Physionet数据库的37例患者和15例对照的记录来创建新的PBL,并比较V1和V2的SPUL。因此,双极V2 - V1是通过从V2测量值中减去V1测量值得到的,始终将V2的SPUL视为正值,V1视为负值。所使用的算法是在每毫秒从同时记录的左电极电压中减去右电极记录的电压。SPUL和PBL的组合可以呈现为描记图或局部环,显示胸骨后位置心脏电水平面的详细信息。PBL V2 - V1反映右心室和室间隔的电活动。

结果

新方法能够检测到SPUL之间向量的变化和毫秒级的差异,并呈现关于从右到左电轴的新的重要信息。在急性前壁心肌梗死和左束支传导阻滞中,可以区分右心室和室间隔的电活动。

结论

SPUL之间的时间/幅度不匹配可能是关于心脏去极化和复极化的丰富新信息的来源。由于在任何能同时记录12导联的心电图设备中已经获取了用于获得PBL和新环的数据,因此该系统可以添加到心电图软件算法中,无需任何额外的电缆或记录工作。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验