To evaluate the shaping ability of four different single-file systems using micro-computed tomography (micro-CT).
Eighty mesiobuccal and mesiolingual canals of permanent mandibular molars were randomly assigned to four groups according to the file used; WaveOne Gold, RECIPROC Blue, HyFlex EDM, and One Shape ( = 20). The samples were scanned using micro-CT for the preinstrumentation record; then the canals were instrumented and scanned for the postinstrumentation records.
The data were then analyzed statistically using one-way analysis of variance (ANOVA) with the level of significance set at α = 0.05.
The results of canal centering ratio and canal transportation showed that no significant difference was found among the four file groups at the middle and the coronal levels. However, a significant difference was found at the apical level ( < 0.05), where WaveOne Gold showed the best centering ratio and the least amount of canal transportation. The change in the canal volume was significant at the coronal level ( < 0.05), whereas the change in the canal volume was higher for the HyFlex EDM group than the other groups. No significant difference was found between the other groups at the apical level, middle level, or in the total percentage of canal volume.
WaveOne Gold produced a more centralized canal preparation with a lesser amount of transportation at the apical level. HyFlex EDM showed the highest canal volumetric change at the coronal level. The interim design of the endodontic files has a high impact on the behavior of the file inside the root canal.
使用微型计算机断层扫描(micro-CT)评估四种不同单根管器械系统的根管预备能力。
根据所使用的器械,将80颗下颌第一恒磨牙的近中颊根和近中舌根随机分为四组;WaveOne Gold、RECIPROC Blue、HyFlex EDM和One Shape(每组 = 20)。使用micro-CT对样本进行术前扫描记录;然后对根管进行预备并扫描以获取术后记录。
然后使用单因素方差分析(ANOVA)对数据进行统计学分析,显著性水平设定为α = 0.05。
根管居中率和根管偏移的结果显示,在根管中部和冠部水平,四组器械之间未发现显著差异。然而,在根尖水平发现了显著差异(P < 0.05),其中WaveOne Gold显示出最佳的居中率和最少的根管偏移量。根管体积在冠部水平的变化具有显著性(P < 0.05),而HyFlex EDM组的根管体积变化高于其他组。在根尖水平、中部水平或根管总体积百分比方面,其他组之间未发现显著差异。
WaveOne Gold在根尖水平能使根管预备更居中,且根管偏移量更少。HyFlex EDM在冠部水平显示出最高的根管体积变化。牙髓治疗器械的临时设计对根管内器械的性能有很大影响。