Pediatr Radiol. 2020 Apr;50(4):596-606. doi: 10.1007/s00247-019-04611-1. Epub 2020 Feb 13.
Contrast-enhanced ultrasonography (US) has become an important supplementary tool in many clinical applications in children. Contrast-enhanced voiding urosonography and intravenous US contrast agents have proved useful in routine clinical practice. Other applications of intracavitary contrast-enhanced US, particularly in children, have not been widely investigated but could serve as a practical and radiation-free problem-solver in several clinical settings. Intracavitary contrast-enhanced US is a real-time imaging modality similar to fluoroscopy with iodinated contrast agent. The US contrast agent solution is administered into physiological or non-physiological body cavities. There is no definitive list of established indications for intracavitary US contrast agent application. However, intracavitary contrast-enhanced US can be used for many clinical applications. It offers excellent real-time spatial resolution and allows for a more accurate delineation of the cavity anatomy, including the internal architecture of complex collections and possible communications within the cavity or with the surrounding structures through fistulous tracts. It can provide valuable information related to the insertion of catheters and tubes, and identify related complications such as confirming the position and patency of a catheter and identifying causes for drainage dysfunction or leakage. Patency of the ureter and biliary ducts can be evaluated, too. US contrast agent solution can be administered orally or a via nasogastric tube, or as an enema to evaluate the gastrointestinal tract. In this review we present potential clinical applications and procedural and dose recommendations regarding intracavitary contrast-enhanced ultrasonography.
对比增强超声(US)已成为儿童许多临床应用中的重要辅助工具。对比增强排空超声和静脉内 US 造影剂已被证明在常规临床实践中有用。腔内对比增强 US 的其他应用,特别是在儿童中,尚未广泛研究,但在几种临床情况下可能作为一种实用且无辐射的问题解决方案。腔内对比增强 US 是一种类似于含碘造影剂的实时成像方式。US 造影剂溶液被注入生理或非生理体腔中。腔内 US 造影剂应用的明确适应证尚无定论。然而,腔内对比增强 US 可用于许多临床应用。它提供了极好的实时空间分辨率,并能够更准确地描绘腔室解剖结构,包括复杂积液的内部结构以及腔室内或通过瘘管与周围结构之间可能的连通。它可以提供与导管和管子插入相关的有价值的信息,并识别相关并发症,例如确认导管的位置和通畅性,并确定引流功能障碍或泄漏的原因。输尿管和胆管的通畅性也可以评估。US 造影剂溶液可以口服或通过鼻胃管给予,也可以灌肠以评估胃肠道。在这篇综述中,我们介绍了腔内对比增强超声的潜在临床应用以及程序和剂量建议。