心室辅助装置患者驱动线出口部位的伤口护理:一项系统综述。

Wound care of the driveline exit site in patients with a ventricular assist device: A systematic review.

作者信息

Özdemir Zeliha, Şenol Çelik Sevilay

机构信息

Surgical Nursing Department, Hacettepe University Faculty of Nursing, Ankara, Turkey.

出版信息

Turk Gogus Kalp Damar Cerrahisi Derg. 2018 Apr 30;26(2):328-335. doi: 10.5606/tgkdc.dergisi.2018.14982. eCollection 2018 Apr.

Abstract

BACKGROUND

This study aims to systematically define and analyze the studies on driveline exit site care methods for patients with a ventricular assist device.

METHODS

The studies related to driveline exit site care of the patients with a ventricular assist device published in English and Turkish between 2008 and 2017 were reviewed from the international Science Direct, PubMed, Web of Science, Scopus, and the national databases. Of a total of 83 articles, a total of seven research articles which met the inclusion criteria were included in the study.

RESULTS

Findings related to the agents used in the cleaning of the driveline exit site, dressing closures, dressing change frequency, and use of driveline anchoring devices were obtained from studies included in the research. It was found that chlorhexidine solution for skin cleaning and sterile gauze sheets and transparent covering for dressing closure were the most preferred methods for the driveline exit site care. Dressing change frequency varied considerably from center to center and anchoring devices were used in all studies.

CONCLUSION

There is no gold standard method for the driveline exit site care of patients with a ventricular assist device and researches on the driveline exit site care seem to be limited. It is recommended that large-scale, randomized-controlled studies should be conducted which would provide a stronger proof of the driveline exit site care.

摘要

背景

本研究旨在系统地界定和分析关于心室辅助装置患者驱动线出口部位护理方法的研究。

方法

从国际科学Direct、PubMed、科学网、Scopus以及国家数据库中检索2008年至2017年间以英文和土耳其文发表的与心室辅助装置患者驱动线出口部位护理相关的研究。在总共83篇文章中,共有7篇符合纳入标准的研究文章被纳入本研究。

结果

从纳入研究的文章中获得了与驱动线出口部位清洁所用制剂、敷料封闭、换药频率以及驱动线固定装置使用情况相关的研究结果。结果发现,用于皮肤清洁的氯己定溶液以及用于敷料封闭的无菌纱布片和透明覆盖物是驱动线出口部位护理最常用的方法。各中心之间的换药频率差异很大,并且所有研究均使用了固定装置。

结论

对于心室辅助装置患者的驱动线出口部位护理,尚无金标准方法,且关于驱动线出口部位护理的研究似乎有限。建议开展大规模随机对照研究,以更有力地证明驱动线出口部位护理的效果。

相似文献

1
Wound care of the driveline exit site in patients with a ventricular assist device: A systematic review.
Turk Gogus Kalp Damar Cerrahisi Derg. 2018 Apr 30;26(2):328-335. doi: 10.5606/tgkdc.dergisi.2018.14982. eCollection 2018 Apr.
2
Driveline exit-site care protocols in patients with left ventricular assist devices: a systematic review.
Eur J Cardiothorac Surg. 2021 Sep 11;60(3):506-515. doi: 10.1093/ejcts/ezab195.
3
Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients.
Heart Lung. 2015 May-Jun;44(3):225-9. doi: 10.1016/j.hrtlng.2015.02.001. Epub 2015 Mar 6.
4
Driveline dressings used in heartmate patients and local complications: A retrospective cohort.
Heart Lung. 2023 Nov-Dec;62:271-277. doi: 10.1016/j.hrtlng.2023.08.007. Epub 2023 Aug 25.
5
Low Incidence of Pump-Related Infections in Jarvik 2000 Ventricular Assist Device Recipients with a Subcostal Driveline Exit Site.
Tex Heart Inst J. 2019 Jun 1;46(3):179-182. doi: 10.14503/THIJ-15-5708. eCollection 2019 Jun.
7
A simple device to secure ventricular assist device driveline and prevent exit-site infection.
Interact Cardiovasc Thorac Surg. 2014 Apr;18(4):415-7. doi: 10.1093/icvts/ivt549. Epub 2014 Jan 14.
8
Treatment of fungal infection on left ventricle assist device driveline exit site: a case report and systematic review.
J Wound Care. 2023 Sep 1;32(Sup9a):cxc-cxciv. doi: 10.12968/jowc.2023.32.Sup9a.cxc.
9

本文引用的文献

1
Substantial Reduction in Driveline Infection Rates With the Modification of Driveline Dressing Protocol.
J Card Fail. 2018 Nov;24(11):746-752. doi: 10.1016/j.cardfail.2018.07.464. Epub 2018 Aug 8.
5
Left ventricular assist device driveline infections: recent advances and future goals.
J Thorac Dis. 2015 Dec;7(12):2151-7. doi: 10.3978/j.issn.2072-1439.2015.11.06.
6
Seventh INTERMACS annual report: 15,000 patients and counting.
J Heart Lung Transplant. 2015 Dec;34(12):1495-504. doi: 10.1016/j.healun.2015.10.003. Epub 2015 Oct 8.
7
Continuous-flow left ventricular assist devices and usefulness of a standardized strategy to reduce drive-line infections.
J Heart Lung Transplant. 2016 Jan;35(1):108-114. doi: 10.1016/j.healun.2015.06.010. Epub 2015 Jun 18.
8
Special Treatment and Wound Care of the Driveline Exit Site after Left Ventricular Assist Device Implantation.
Thorac Cardiovasc Surg. 2015 Dec;63(8):670-4. doi: 10.1055/s-0035-1554961. Epub 2015 Jul 15.
9
Preoperative skin antiseptics for preventing surgical wound infections after clean surgery.
Cochrane Database Syst Rev. 2015 Apr 21;2015(4):CD003949. doi: 10.1002/14651858.CD003949.pub4.
10
Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients.
Heart Lung. 2015 May-Jun;44(3):225-9. doi: 10.1016/j.hrtlng.2015.02.001. Epub 2015 Mar 6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验