双能 CT 检测急性肺栓塞的诊断准确性:系统评价和荟萃分析。

Diagnostic Accuracy of Dual-Energy CT in Detection of Acute Pulmonary Embolism: A Systematic Review and Meta-Analysis.

机构信息

Department of Radiology, 8167Vancouver General Hospital/University of British Colombia, Vancouver, Canada.

Faculty of Medicine, Zagazig University, Zagazig, Egypt.

出版信息

Can Assoc Radiol J. 2021 May;72(2):285-292. doi: 10.1177/0846537120902062. Epub 2020 Feb 27.

Abstract

PURPOSE

In this systematic review and meta-analysis, we aimed to investigate the accuracy of dual-energy computed tomography (DECT) in the detection of acute pulmonary embolism (PE).

METHODS

We searched Medline (via PubMed), EBSCO, Web of Science, Scopus, and the Cochrane Library for relevant published studies. We selected studies assessing the accuracy of DECT in the detection of PE. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies-2 tool. Meta-analysis was performed to calculate mean estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR). The summary receiver operating characteristic (sROC) curve was drawn to get the Cochran Q-index and the area under the curve (AUC).

RESULTS

Seven studies were included in our systematic review. Of the 182 patients included, 108 patients had PEs. The pooled analysis showed an overall sensitivity and specificity of 88.9% (95% confidence interval [CI]: 81.4%-94.1%) and 94.6% (95% CI: 86.7%-98.5%), respectively. The pooled PLR was 8.186 (95% CI: 3.726-17.986), while the pooled NLR was 0.159 (95% CI: 0.093-0.270). Cochran-Q was 0.8712, and AUC was 0.935 in the sROC curve.

CONCLUSION

Dual-energy computed tomography shows high sensitivity, specificity, and diagnostic accuracy in the detection of acute PE. The high PLR highlights the high clinical importance of DECT as a prevalence-independent, rule-in test. Studies with a larger sample size with standardized reference tests are still needed to increase the statistical power of the study and support these findings.

摘要

目的

在这项系统评价和荟萃分析中,我们旨在研究双能 CT(DECT)在急性肺栓塞(PE)检测中的准确性。

方法

我们在 Medline(通过 PubMed)、EBSCO、Web of Science、Scopus 和 Cochrane 图书馆中搜索了相关的已发表研究。我们选择了评估 DECT 在 PE 检测中的准确性的研究。使用诊断准确性研究质量 2 工具(Quality of Diagnostic Accuracy Studies-2 tool)对偏倚和适用性进行质量评估。进行荟萃分析以计算敏感性、特异性、阳性似然比(PLR)和阴性似然比(NLR)的平均估计值。绘制汇总受试者工作特征(sROC)曲线以获得 Cochran Q 指数和曲线下面积(AUC)。

结果

我们的系统评价纳入了 7 项研究。在纳入的 182 名患者中,有 108 名患者患有 PE。汇总分析显示,总体敏感性和特异性分别为 88.9%(95%置信区间 [CI]:81.4%-94.1%)和 94.6%(95% CI:86.7%-98.5%)。汇总 PLR 为 8.186(95% CI:3.726-17.986),而汇总 NLR 为 0.159(95% CI:0.093-0.270)。sROC 曲线中的 Cochran-Q 为 0.8712,AUC 为 0.935。

结论

DECT 在检测急性 PE 方面具有较高的敏感性、特异性和诊断准确性。高 PLR 突出了 DECT 作为一种与患病率无关的、规则内检测的重要临床意义。仍需要更大样本量的研究,并使用标准化参考测试,以提高研究的统计效力并支持这些发现。