When CO escapes from plasma, the pH of the plasma increases. In samples left open or kept in long-term storage, the pH may increase considerably. Assays in which the ratio of plasma sample relative to the total volume including reagents is high may be sensitive to the pH of the plasma sample.
The aim was to investigate the effect of the pH of plasma samples used in the calibrated automated thrombin generation (CAT) assay in which the ratio (plasma sample) / (total volume) is high.
Plasma pH was increased by allowing CO to escape in open beakers before the CAT analysis. The effect of pH was also investigated by mixing plasma with buffers with different pH levels.
At a pH close to 8.0, endogenous thrombin potential (ETP) and peak decreased considerably, whereas lagtime and time-to-peak were modestly increased. Mixtures of plasma and buffer with pH levels between 7 and 8 showed that ETP and peak decreased at alkaline pH; lagtime and time-to-peak were higher at acidic pH levels but were shortened, partly in contrast to first results, at alkaline pH levels. The addition of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid buffer to plasma with a high pH attenuated the effects; however, the effect was most significant if added before the CO escaped.
Modifications of plasma pH can significantly alter thrombin generation. In alkaline samples, for example, after lengthy storage in a freezer where pH can increase considerably, thrombin generation is lowered. To minimize this effect, plasma should be stored in tubes filled to the maximum volume.
当一氧化碳从血浆中逸出时,血浆的pH值会升高。在敞口放置或长期储存的样本中,pH值可能会大幅上升。血浆样本与包括试剂在内的总体积之比很高的检测可能对血浆样本的pH值敏感。
旨在研究在校准自动凝血酶生成(CAT)检测中使用的血浆样本pH值的影响,该检测中(血浆样本)/(总体积)的比例很高。
在进行CAT分析之前,通过让一氧化碳在敞口烧杯中逸出来提高血浆pH值。还通过将血浆与不同pH值的缓冲液混合来研究pH值的影响。
在接近8.0的pH值下,内源性凝血酶潜力(ETP)和峰值大幅下降,而延迟时间和达到峰值的时间略有增加。血浆与pH值在7至8之间的缓冲液的混合物表明,在碱性pH值下ETP和峰值下降;在酸性pH值下延迟时间和达到峰值的时间较高,但在碱性pH值下部分与最初结果相反,延迟时间和达到峰值的时间缩短。向高pH值的血浆中添加4-(2-羟乙基)-1-哌嗪乙磺酸缓冲液可减弱这种影响;然而,如果在一氧化碳逸出之前添加,效果最为显著。
血浆pH值的改变可显著改变凝血酶生成。例如,在碱性样本中,在冷冻箱中长时间储存后pH值会大幅升高,凝血酶生成会降低。为了将这种影响降至最低,血浆应储存在装满至最大体积的试管中。