Auburn University, Auburn, AL.
Western University, Ontario, Canada.
J Am Acad Audiol. 2020 Jul;31(7):496-505. doi: 10.3766/jaaa.19017. Epub 2020 Sep 2.
Pediatric hearing instrument fitting is optimally performed with individually obtained real-ear-to-coupler difference (RECD) measurements. If these measurements cannot be obtained, predicted values based on age are used. Recent evidence obtained from children aged 3-11 years suggests that head circumference (HC) may be a viable alternative or addition to age for use in RECD prediction.
The purpose of the present study was to determine if HC can be used to predict RECDs in infants, children, and adults.
A correlational design was used. HC and RECD values were measured in all participants.
Participants were 278 North American infants and children (136 males and 142 females) aged 1.6 months to 11 years and 109 adults (42 males and 67 females) aged 18 years to 83 years.
After otoscopic inspection and immittance measurements were performed to assess candidacy for inclusion in the study, HC was measured twice for all participants and a single RECD measure was obtained for each participant at twelve frequencies (250 through 12500 Hz). The reliability of HC measurements was assessed with an intraclass correlation analysis. Linear regression analyses were performed with age and HC as predictor variables and RECDs as the dependent variable.
Analysis indicated good reliability of the HC measurement. The relationships between RECD and HC were comparable with the relationships between RECD and age. Combining HC and age did not improve predictive accuracy.
HC can be used in children and adults as an alternative metric in the prediction of RECDs when individual RECDs cannot be obtained.
儿科听力仪器的适配最佳是通过单独获得的真耳-耦合器差值(RECD)测量来完成。如果无法获得这些测量值,则使用基于年龄的预测值。最近从 3-11 岁儿童获得的证据表明,头围(HC)可能是替代或补充年龄的可行方法,可用于 RECD 预测。
本研究旨在确定 HC 是否可用于预测婴儿、儿童和成人的 RECD。
采用相关性设计。所有参与者均测量 HC 和 RECD 值。
参与者为 278 名北美婴儿和儿童(136 名男性和 142 名女性),年龄为 1.6 个月至 11 岁,以及 109 名成年人(42 名男性和 67 名女性),年龄为 18 岁至 83 岁。
在进行耳镜检查和导抗测量以评估是否有资格参加研究之后,对所有参与者进行了两次 HC 测量,并为每个参与者在 12 个频率(250 至 12500 Hz)获得了单个 RECD 测量。使用组内相关系数分析评估 HC 测量的可靠性。使用年龄和 HC 作为预测变量,RECD 作为因变量进行线性回归分析。
分析表明 HC 测量具有良好的可靠性。RECD 与 HC 之间的关系与 RECD 与年龄之间的关系相当。将 HC 和年龄结合使用并不能提高预测准确性。
当无法获得个体 RECD 时,HC 可在儿童和成人中用作 RECD 预测的替代指标。