眼防护具为介入放射工作人员提供防护的实验评估综述。

Review of experimental estimates for the protection afforded by eyewear for interventional x-ray staff.

机构信息

Department of Medicine, Epidemiology, Workplace and Environmental Hygiene, National Institute for Insurance against Accidents at Work (INAIL), via Fontana Candida 1, 00078 Monte Porzio Catone, Roma, Italy.

出版信息

J Radiol Prot. 2020 Jun;40(2):R46-R70. doi: 10.1088/1361-6498/ab7d8c. Epub 2020 Mar 6.

Abstract

This paper attempts to systematise all published experimental results for the dose reduction factor (DRF) offered by leaded eyewear on clinicians performing interventional procedures. We aim to present a comprehensive analysis of the issue and a comparison of the various equipment models at different exposure geometries. The main purpose of the paper is, however, to clarify the best choice for the DRF within the possible diverse contexts and approaches to eye lens dose assessment. Evidence has been obtained that the lowest estimates of DRF are associated with larger scatter incidence angles and that, except for the slightly better performance exhibited by wraparound eyeglasses, there is no real distinction between the DRFs for the different equipment categories. The dataset as a whole confirms that, when measurements for the concerned eyewear model and irradiation conditions are unattainable, assuming DRF = 2 represents an adequately conservative choice. Nonetheless, this value includes only 17% of all results from the literature, whereas their histogram follows a distribution skewed towards higher values, represented by a median equal to 5. Therefore, if more realistic dose reconstructions are necessary, such as for purposes of epidemiological investigations or compensation decisions, the adoption of this central tendency index appears to be more reasonable. The complexity of characterising the DRF behaviour as a function of the various exposure factors reinforces the consideration of a statistical approach to eye lens dose assessment as a viable alternative. In this perspective, assuming for DRF a lognormal distribution with parameters [Formula: see text] and [Formula: see text] which has been verified to satisfactorily approximate the literature data distribution, should be deemed to be an appropriate option.

摘要

本文旨在系统整理关于临床医生在介入手术中使用含铅眼镜时提供的剂量减少因子(DRF)的所有已发表的实验结果。我们旨在对这一问题进行全面分析,并对不同暴露几何形状下的各种设备模型进行比较。然而,本文的主要目的是在可能的不同环境和眼晶状体剂量评估方法中,明确 DRF 的最佳选择。有证据表明,DRF 的最低估计值与更大的散射入射角度相关,而且除了全包式眼镜表现出略好的性能外,不同设备类别之间的 DRF 没有真正的区别。整个数据集证实,当无法获得有关眼镜模型和照射条件的测量值时,假设 DRF=2 是一个足够保守的选择。然而,该值仅包含文献中所有结果的 17%,而其直方图则呈现出向更高值偏斜的分布,中位数等于 5。因此,如果需要更现实的剂量重建,例如进行流行病学调查或赔偿决策,采用这种中心趋势指数似乎更为合理。由于要根据各种暴露因素来描述 DRF 行为的复杂性,因此将眼部晶状体剂量评估的统计方法视为可行的替代方法。在这种情况下,假设 DRF 具有参数 [公式:见文本]和[公式:见文本]的对数正态分布,并且已经验证该分布可以很好地近似文献数据分布,应被视为一种合适的选择。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验