Suppr超能文献

CPT 管与 Lymphoprep 管分离的 PBMCs 的功能比较。

Functional comparison of PBMCs isolated by Cell Preparation Tubes (CPT) vs. Lymphoprep Tubes.

机构信息

Department of Microbiology & Immunology, Stanford University School of Medicine, Stanford, CA, USA.

WCCT Global Inc., Cypress, CA, USA.

出版信息

BMC Immunol. 2020 Mar 30;21(1):15. doi: 10.1186/s12865-020-00345-0.

Abstract

BACKGROUND

Cryopreserved human peripheral blood mononuclear cells (PBMCs) are a commonly used sample type for a variety of immunological assays. Many factors can affect the quality of PBMCs, and careful consideration and validation of an appropriate PBMC isolation and cryopreservation method is important for well-designed clinical studies. A major point of divergence in PBMC isolation protocols is the collection of blood, either directly into vacutainers pre-filled with density gradient medium or the use of conical tubes containing a porous barrier to separate the density gradient medium from blood. To address potential differences in sample outcome, we isolated, cryopreserved, and compared PBMCs using parallel protocols differing only in the use of one of two common tube types for isolation.

METHODS

Whole blood was processed in parallel using both Cell Preparation Tubes™ (CPT, BD Biosciences) and Lymphoprep™ Tubes (Axis-Shield) and assessed for yield and viability prior to cryopreservation. After thawing, samples were further examined by flow cytometry for cell yield, cell viability, frequency of 10 cell subsets, and capacity for stimulation-dependent CD4+ and CD8+ T cell intracellular cytokine production.

RESULTS

No significant differences in cell recovery, viability, frequency of immune cell subsets, or T cell functionality between PBMC samples isolated using CPT or Lymphoprep tubes were identified.

CONCLUSION

CPT and Lymphoprep tubes are effective and comparable methods for PBMC isolation for immunological studies.

摘要

背景

冷冻保存的人外周血单核细胞(PBMCs)是各种免疫测定中常用的样本类型。许多因素会影响 PBMCs 的质量,因此仔细考虑并验证适当的 PBMC 分离和冷冻保存方法对于精心设计的临床研究非常重要。PBMC 分离方案的一个主要分歧点是血液的采集,要么直接采集到预先填充密度梯度介质的真空采血管中,要么使用含有多孔屏障的锥形管将密度梯度介质与血液分离。为了解决样本结果的潜在差异,我们使用两种常见管类型之一进行平行分离方案来分离、冷冻保存和比较 PBMCs。

方法

使用 Cell Preparation Tubes™(CPT,BD Biosciences)和 Lymphoprep™ Tubes(Axis-Shield)平行处理全血,并在冷冻保存前评估产量和活力。解冻后,通过流式细胞术进一步检查样品的细胞产量、细胞活力、10 个细胞亚群的频率以及刺激依赖性 CD4+和 CD8+T 细胞细胞内细胞因子产生的能力。

结果

使用 CPT 或 Lymphoprep 管分离的 PBMC 样本在细胞回收、活力、免疫细胞亚群的频率或 T 细胞功能方面没有显著差异。

结论

CPT 和 Lymphoprep 管是用于免疫研究的 PBMC 分离的有效且可比较的方法。