Suppr超能文献

用于直接检测雾化甲型流感病毒颗粒的微重力免疫传感器。

Microgravimetric immunosensor for direct detection of aerosolized influenza A virus particles.

作者信息

Owen Thomas W, Al-Kaysi Rabih O, Bardeen Christopher J, Cheng Quan

机构信息

Department of Chemistry, University of California, Riverside, CA 92521, United States.

出版信息

Sens Actuators B Chem. 2007 Oct 1;126(2):691-699. doi: 10.1016/j.snb.2007.04.028. Epub 2007 Apr 24.

Abstract

The development and characterization of a quartz crystal microbalance (QCM) sensor for the direct detection of aerosolized influenza A virions is reported. Self-assembled monolayers (SAMs) of mercaptoundecanoic acid (MUA) are formed on QCM gold electrodes to provide a surface amenable for the immobilization of anti-influenza A antibodies using NHS/EDC coupling chemistry. The surface-bound antibody provides a selective and specific sensing interface for the capture of influenza virions. A nebulizer is used to create aerosolized samples and is directly connected to a chamber housing the antibody-modified crystal ("immunochip"). Upon exposure to the aerosolized virus, the interaction between the antibody and virus leads to a dampening of the oscillation frequency of the quartz crystal. The magnitude of frequency change is directly related to virus concentration. Control experiments using aerosols from chicken egg allantoic fluid and an anti-murine antibody based immunosensor confirm that the observed signal originates from specific viral binding on the chip surface. Step-by-step surface modification of MUA assembly, antibody attachment, and antibody-virus interaction are characterized by atomic force microscopy (AFM) imaging analysis. Using the / = 3 principle, the limit of detection is estimated to be 4 virus particles/mL. The high sensitivity and real-time sensing scheme presented here can play an important role in the public health arena by offering a new analytical tool for identifying bio-contaminated areas and assisting in timely patient diagnosis.

摘要

本文报道了一种用于直接检测雾化甲型流感病毒粒子的石英晶体微天平(QCM)传感器的研制与表征。在QCM金电极上形成巯基十一烷酸(MUA)的自组装单分子层(SAMs),以提供一个适合使用NHS/EDC偶联化学固定抗甲型流感抗体的表面。表面结合的抗体为捕获流感病毒粒子提供了一个选择性和特异性的传感界面。使用雾化器产生雾化样品,并将其直接连接到容纳抗体修饰晶体(“免疫芯片”)的腔室。当暴露于雾化病毒时,抗体与病毒之间的相互作用会导致石英晶体振荡频率的衰减。频率变化的幅度与病毒浓度直接相关。使用来自鸡胚尿囊液的气溶胶和基于抗鼠抗体的免疫传感器进行的对照实验证实,观察到的信号源自芯片表面的特异性病毒结合。通过原子力显微镜(AFM)成像分析对MUA组装、抗体附着和抗体 - 病毒相互作用的逐步表面修饰进行了表征。使用/ = 3原则,估计检测限为4个病毒颗粒/毫升。本文提出的高灵敏度和实时传感方案可为识别生物污染区域和协助及时诊断患者提供一种新的分析工具,在公共卫生领域发挥重要作用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c50e/7127275/89a6905392c0/sc1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验