Abstract

BACKGROUND

The majority of dogs with idiopathic epilepsy continue to have seizures despite appropriate treatment.

OBJECTIVES

To assess the use of a commercially available, collar-mounted accelerometer to detect generalized seizures in dogs.

ANIMALS

Twenty two client-owned dogs with idiopathic epilepsy.

METHODS

Six-month prospective clinical study during which dogs wore a collar-mounted accelerometer. Seizure documentation was based on owner observations and video recordings. The accelerometer used a predefined algorithm to detect seizures in the first study phase, and an individualized algorithm in the second study phase. Caregivers completed a quality of life (QoL) questionnaire at the initial and final study visit.

RESULTS

Using the predefined algorithm, the accelerometer detected seizures with a sensitivity of 18.6% (95% CI [13.4%, 23.8%]) and mean false detection rate of 0.096/day. Values did not change significantly with use of an individualized algorithm (sensitivity 22.1%, 95% CI [15.1%, 29.0%]; false detection rate 0.054/day). Mean composite QoL score was significantly improved at study completion (50.42) compared to study initiation (39.53; P = .005), and this change was moderately correlated with a change in weekly exercise (r = 0.46, P = .05).

CONCLUSIONS AND CLINICAL IMPORTANCE

Generalized seizures in dogs can be detected with a collar-mounted accelerometer, but the overall sensitivity is low.

摘要

背景

尽管进行了适当的治疗,大多数患有特发性癫痫的狗仍会继续发作。

目的

评估市售的、戴在项圈上的加速度计在检测狗的全身性癫痫发作中的应用。

动物

22 只患有特发性癫痫的犬。

方法

6 个月的前瞻性临床研究期间,狗佩戴项圈式加速度计。根据主人的观察和视频记录进行癫痫发作记录。加速度计在第一研究阶段使用预定义的算法来检测癫痫发作,在第二研究阶段使用个性化的算法。在最初和最终的研究访问时,护理人员完成了生活质量(QoL)问卷。

结果

使用预定义算法,加速度计检测到的癫痫发作的敏感性为 18.6%(95%CI[13.4%,23.8%]),平均假阳性检测率为 0.096/天。使用个性化算法时,值没有显著变化(敏感性 22.1%,95%CI[15.1%,29.0%];假阳性检测率 0.054/天)。与研究开始时相比(39.53),研究完成时(50.42)的综合 QoL 评分显著提高(P =0.005),且这种变化与每周运动的变化中度相关(r =0.46,P =0.05)。

结论和临床意义

可以使用戴在项圈上的加速度计检测狗的全身性癫痫发作,但总体敏感性较低。