Thromboelastography (TEG) and rotational thromboelastometry (ROTEM) are point-of-care viscoelastic devices that use whole blood samples to assess coagulation and fibrinolysis. These devices have been studied extensively in cardiac surgery, but there is limited robust evidence supporting its use in obstetrics. The hesitancy toward its routine use in obstetrics may be due to the current lack of randomized controlled trials and large observational studies. The study aims to systematically review studies that investigated TEG/ROTEM use in pregnancy or peripartum, and to provide recommendations for future studies to fill current research gaps. We performed a systematic review of studies on viscoelastic testing in obstetrics. Included studies were original research, used TEG or ROTEM during pregnancy or peripartum, and published in English. Ninety-three studies, spanning 31 years from 1989 to 2020 and with a total of 32,817 participants, were included. Sixty-two (66.7%) of the studies used TEG and 31 (33.3%) used ROTEM. To date, there are a total of two randomized controlled trials on TEG/ROTEM use in obstetrics. ROTEM may be used to guide transfusion therapy for postpartum hemorrhage. TEG and ROTEM can detect the hypercoagulable changes associated with pregnancy. Variability between study protocols and results suggests the need for future large prospective high-quality studies with standardized protocols to investigate the utility of TEG/ROTEM in assessing risk for thrombosis and hemorrhage as well as in guiding prophylaxis and treatment in obstetric patients. This review identifies the gaps and provides concrete recommendations for future studies to fill those gaps.

摘要

血栓弹力图(TEG)和旋转血栓弹力测定法(ROTEM)是即时检测的粘弹性设备,它们使用全血样本评估凝血和纤维蛋白溶解情况。这些设备在心脏手术中已得到广泛研究,但在产科中支持其使用的有力证据有限。对其在产科常规使用的犹豫可能是由于目前缺乏随机对照试验和大型观察性研究。本研究旨在系统回顾调查TEG/ROTEM在妊娠或围产期使用情况的研究,并为未来研究提供建议以填补当前的研究空白。我们对产科粘弹性检测的研究进行了系统回顾。纳入的研究为原创性研究,在妊娠或围产期使用了TEG或ROTEM,且以英文发表。纳入了93项研究,时间跨度从1989年至2020年共31年,共有32,817名参与者。其中62项(66.7%)研究使用了TEG,31项(33.3%)使用了ROTEM。迄今为止,关于TEG/ROTEM在产科使用的随机对照试验共有两项。ROTEM可用于指导产后出血的输血治疗。TEG和ROTEM能够检测与妊娠相关的高凝变化。研究方案和结果之间的差异表明,未来需要开展大型前瞻性高质量研究,采用标准化方案来调查TEG/ROTEM在评估产科患者血栓形成和出血风险以及指导预防和治疗方面的效用。本综述确定了差距,并为未来研究填补这些差距提供了具体建议。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验