基于高灵敏度化学发光的侧向流动免疫分析法检测人血清中心肌肌钙蛋白 I。

Highly Sensitive Chemiluminescence-Based Lateral Flow Immunoassay for Cardiac Troponin I Detection in Human Serum.

机构信息

Department of Chemistry, Gwangju Institute of Science and Technology (GIST), 123 Cheomdangwagi-ro, Buk-gu, Gwangju 61005, Korea.

出版信息

Sensors (Basel). 2020 May 2;20(9):2593. doi: 10.3390/s20092593.

Abstract

Lateral flow assays (LFAs) have become the most common biosensing platforms for point-of-care testing due to their compliance with the ASSURED (affordable, sensitive, specific, user-friendly, rapid/robust, equipment-free, and deliverable to end-users) guidelines stipulated by the World Health Organization. However, the limited analytical sensitivity and low quantitative capability of conventional LFAs, which use gold nanoparticles (AuNPs) for colorimetric labeling, have prevented high-performance testing. Here, we report the development of a highly sensitive chemiluminescence (CL)-based LFA involving AuNPs conjugated with aldehyde-activated peroxidase and antibody molecules-i.e., AuNP-(ald)HRP-Ab-as a new conjugation scheme for high-performance testing in LFAs. When paired with the CL-based signal readout modality, the AuNP-(ald)HRP-Ab conjugate resulted in 110-fold enhanced sensitivity over the colorimetric response of a typical AuNP-Ab conjugate. To evaluate the performance of the CL-based LFA, we tested it with human cardiac troponin I (cTnI; a standard cardiac biomarker used to diagnose myocardial infarction) in standard and clinical serum samples. Testing the standard samples revealed a detection limit of 5.6 pg·mL and acceptably reliable precision (with a coefficient of variation of 2.3%-8.4%), according to clinical guidelines. Moreover, testing the clinical samples revealed a high correlation (r = 0.97) with standard biochemical analyzers, demonstrating the potential clinical utility of the CL-based LFA for high-performance cTnI testing.

摘要

侧向流动分析(LFA)因其符合世界卫生组织(WHO)规定的“可负担、敏感、特异、用户友好、快速/稳健、无需设备、可交付给终端用户”(ASSURED)准则,已成为即时检测中最常用的生物传感平台。然而,传统的侧向流动分析(LFA)使用金纳米粒子(AuNPs)进行比色标记,其分析灵敏度有限,定量能力较低,限制了高性能检测。在此,我们报告了一种高灵敏度的基于化学发光(CL)的 LFA 的开发,该方法涉及与醛激活过氧化物酶和抗体分子偶联的 AuNPs,即 AuNP-(ald)HRP-Ab,作为用于 LFA 中高性能检测的新偶联方案。当与基于 CL 的信号读出模式结合使用时,AuNP-(ald)HRP-Ab 偶联物比典型的 AuNP-Ab 偶联物的比色响应提高了 110 倍的灵敏度。为了评估基于 CL 的 LFA 的性能,我们用人心脏肌钙蛋白 I(cTnI;用于诊断心肌梗死的标准心脏生物标志物)在标准和临床血清样本中对其进行了测试。根据临床指南,标准样品的测试结果显示检测限为 5.6 pg·mL,且具有可接受的可靠精密度(变异系数为 2.3%-8.4%)。此外,对临床样本的测试结果表明,与标准生化分析仪具有高度相关性(r = 0.97),证明了基于 CL 的 LFA 用于高性能 cTnI 检测的潜在临床应用价值。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d182/7248921/8779f9dbd779/sensors-20-02593-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索