Suppr超能文献

数年植入期后,周围组织对非骨水泥型髋关节植入物Ti-6Al-4V的反应。三例尸检研究。

Reactions of surrounding tissue to the cementless hip implant Ti-6Al-4V after an implantation period of several years. Autopsy studies in three cases.

作者信息

Lintner F, Zweymüller K, Böhm G, Brand G

机构信息

Institute for Pathological Anatomy, University of Vienna, Austria.

出版信息

Arch Orthop Trauma Surg (1978). 1988;107(6):357-63. doi: 10.1007/BF00381062.

Abstract

Three femoral endoprosthetic stems implanted without cement, made of Ti-6Al-4V alloy, with implantation periods of between 2 and 4 years were examined histologically in the form of undecalcified thin ground sections after having been split into segments and embedded in plastic. During the implantation period total osseointegration in the metadiaphyseal region takes place, while in the proximal area reaction forms with direct contact between metal and bone on the one hand and with an interposed membrane of connective tissue and adjacent secondary bony shell on the other must be distinguished. The osseointegration of the stem is the result of a primary healing of the bone and is due to the biocompatibility of the metal alloy and to the primary stability obtained by the press-fit method.

摘要

对三根未使用骨水泥植入的股骨假体柄进行了组织学检查,这些假体柄由Ti-6Al-4V合金制成,植入时间为2至4年。将其切成段并嵌入塑料后,以未脱钙的薄磨片形式进行检查。在植入期间,干骺端区域会发生完全骨整合,而在近端区域,一方面要区分金属与骨直接接触的反应形式,另一方面要区分有结缔组织膜和相邻继发性骨壳插入的反应形式。假体柄的骨整合是骨一期愈合的结果,这归因于金属合金的生物相容性以及压配法获得的初始稳定性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验