Suppr超能文献

建筑外墙朝向对涂覆灰泥和石膏的建筑外墙中杀生物剂浸出的影响。

Influence of façade orientation on the leaching of biocides from building façades covered with mortars and plasters.

机构信息

Department Environment, Hygiene and Sensor Technology, Fraunhofer Institute for Building Physics IBP, Fraunhoferstraße 10, 83626 Valley, Germany; Chair of Urban Water Systems Engineering, Technical University of Munich, Am Coulombwall 3, 85748 Garching, Germany.

Department Environment, Hygiene and Sensor Technology, Fraunhofer Institute for Building Physics IBP, Fraunhoferstraße 10, 83626 Valley, Germany.

出版信息

Sci Total Environ. 2020 Sep 10;734:139465. doi: 10.1016/j.scitotenv.2020.139465. Epub 2020 May 16.

Abstract

Biocides used in building façades to prevent potential growth of algae, fungi and bacteria are of major concern regarding the quality of stormwater runoff. The aim of the study was to analyze the influence of the façade orientation on the biocide release under real weather conditions to gain information for the development of on-site treatment systems. Field tests with model houses containing two different plaster compositions were carried out over a period of 18 months. The results of the analyzed rain events demonstrate that façade orientation plays an important role in the leaching loads of biocides. Biocide loads in the runoff decreased corresponding to the wind direction. High cumulated active substance discharges of diuron (149 mg/m), carbendazim (43.5 mg/m), terbutryn (9.3 mg/m) and octylisothiazolinone (OIT) (31.9 mg/m) were found in the runoff of the façades facing the predominant weather orientation. Meanwhile, the highest concentrations of diuron (2.8 mg/L) and OIT (0.7 mg/L) were observed in the runoff from façades with smaller runoff volumes. The obtained results demonstrate that treatment facilities have to be installed at all building sides. The hydraulic and the substance load is highest at the weather side, which has a strong influence on the dimension and the lifetime of the treatment system.

摘要

用于防止藻类、真菌和细菌在建筑立面上潜在生长的杀生剂是关注雨水径流质量的主要因素。本研究的目的是分析在实际天气条件下外墙朝向对杀生剂释放的影响,以获取有关现场处理系统开发的信息。使用含有两种不同石膏成分的模型房屋进行了为期 18 个月的现场测试。分析的降雨事件结果表明,外墙朝向在杀生剂浸出负荷中起着重要作用。雨水径流水生生物杀灭剂的负荷相应地随风向而降低。在朝向主要天气方向的立面上的径流水体中,发现了较高的累积活性物质排放量,其中包括敌草隆(149mg/m)、多菌灵(43.5mg/m)、特丁津(9.3mg/m)和辛基异噻唑啉酮(OIT)(31.9mg/m)。同时,在径流量较小的立面上的径流水体中观察到了较高的敌草隆(2.8mg/L)和 OIT(0.7mg/L)浓度。所得结果表明,必须在所有建筑物侧面安装处理设施。在天气侧,水力和物质负荷最高,这对处理系统的尺寸和寿命有很大影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验