Short-Term Changes in Prediction Error after Cataract Surgery in Eyes Receiving 1 of 3 Types of Single-Piece Acrylic Intraocular Lenses.

机构信息

Hayashi Eye Hospital, Fukuoka, Japan.

Hayashi Eye Hospital, Fukuoka, Japan.

出版信息

Am J Ophthalmol. 2020 Nov;219:12-20. doi: 10.1016/j.ajo.2020.05.031. Epub 2020 May 29.

Abstract

PURPOSE

To compare short-term changes in refractive prediction error (PE) after phacoemulsification among eyes receiving different types of single-piece acrylic intraocular lenses (IOLs).

DESIGN

Randomized clinical trial.

METHODS

A total of 195 eyes of 195 patients scheduled for implantation of a single-piece acrylic IOL were randomly assigned to receive 1 of 3 IOLs: 1) an Alcon model SN60WF, 2) a Hoya model XY-1, or 3) an AMO model ZCB00V. Manifest spherical equivalent (MRSE) value, PE, and changes in PE were examined at 1 day and at 1 and 2 months postoperatively and were compared among groups.

RESULTS

The mean MRSE and PE significantly changed toward myopia between 1 day and 2 months postoperatively in all groups (P < .0001). The MRSE and PE did not differ significantly among groups at 1 day and 1 month postoperatively and were significantly smaller in the SN60WF group than in the XY-1 and ZCB00V groups at 2 months (P ≤ .0006). The PE change between 1 day and 2 months postoperatively was significantly smaller in the SN60WF group than in the other groups (P = .0062). IOL type and changes in anterior chamber depth and corneal curvature independently correlated with PE changes.

CONCLUSIONS

The MRSE and PE showed a significant myopic change for 2 months postoperatively in eyes implanted with 1 of 3 types of single-piece acrylic IOLs and were significantly smaller in the SN60WF than in the XY-1 and ZCB00V groups. Changes in PE during the 2 postoperative months were smaller in the SN60WF IOLs than in the other IOLs, suggesting that postoperative refractive stability differs among single-piece acrylic IOLs.

摘要

目的

比较三种不同类型的单件式丙烯酸人工晶状体(IOL)植入术后短期内预测折射误差(PE)的变化。

设计

随机临床试验。

方法

共 195 例 195 只眼拟植入单件式丙烯酸 IOL 的患者,随机分为三组,分别接受 1)Alcon 型号 SN60WF,2)Hoya 型号 XY-1 或 3)AMO 型号 ZCB00V。在术后 1 天、1 个月和 2 个月时检查等效球镜(MRSE)值、PE 和 PE 的变化,并进行组间比较。

结果

所有组在术后 1 天至 2 个月期间,MRSE 和 PE 均向近视方向显著变化(P<0.0001)。术后 1 天和 1 个月时,三组间 MRSE 和 PE 无显著差异,而在 2 个月时,SN60WF 组的 MRSE 和 PE 均明显小于 XY-1 和 ZCB00V 组(P≤0.0006)。与术后 1 天相比,SN60WF 组在术后 2 个月时的 PE 变化明显较小(P=0.0062)。IOL 类型、前房深度和角膜曲率变化与 PE 变化独立相关。

结论

在植入三种单件式丙烯酸 IOL 中的一种的眼内,术后 2 个月时 MRSE 和 PE 均呈显著的近视性变化,且 SN60WF 组明显小于 XY-1 和 ZCB00V 组。在术后 2 个月期间,SN60WF IOL 的 PE 变化小于其他 IOL,表明单件式丙烯酸 IOL 的术后屈光稳定性不同。