Suppr超能文献

两种一体式丙烯酸可折叠人工晶状体的比较:白内障手术后轴向运动的短期变化及其对屈光的影响。

Comparison of two one-piece acrylic foldable intraocular lenses: Short-term change in axial movement after cataract surgery and its effect on refraction.

机构信息

Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan.

National Hospital Organization, Tokyo Medical Center, Tokyo, Japan.

出版信息

PLoS One. 2022 Aug 30;17(8):e0273431. doi: 10.1371/journal.pone.0273431. eCollection 2022.

Abstract

PURPOSE

To compare the change in intraocular lens (IOL) axial movement, corneal power, and postoperative refraction of eyes implanted with two different single-piece, open loop, acrylic foldable IOLs with planar-haptic design: one IOL with hinges vs. one IOL without hinges. The role of IOL axial movement on short-term refractive shift after cataract surgery was also evaluated.

METHODS

This retrospective comparative study enrolled consecutive patients who had phacoemulsification with aspheric IOL implantation. The IOL depth (the distance from corneal endothelium to IOL surface) and corneal power were measured via anterior-segment optical coherence tomography at 4 days and 1 month postoperatively. The changes in axial movement of the IOL, corneal power, and manifest refractive spherical equivalent (MRSE) were compared among groups, and the correlations between each lens were evaluated.

RESULTS

IOL with hinges was implanted in 42 eyes of 42 patients and IOL without hinges was implanted in 42 eyes of 42 patients. The change in axial movement between 4 days and 1 month was significantly smaller in the IOL with hinges group than in the IOL without hinges group (p < 0.001). The axial movement of IOL with hinges did not correlate with the MRSE change; however, the forward shift of IOL without hinges correlated with the myopic refractive change (Pearson r = 0.62, p < 0.001).

CONCLUSION

The postoperative axial movement of IOL was more stable in the IOL with hinges group than the IOL without hinges group between 4 days and 1 month after cataract surgery. Even though the two study IOLs with planar-haptic design are made of similar acrylic materials, other characteristics such as hinge structure may affect IOL stability in the bag.

摘要

目的

比较两种不同的单件式、开环、丙烯酸可折叠平面襻设计的人工晶状体(IOL)轴向运动、角膜曲率和术后屈光度的变化:一种有铰链的 IOL 与一种无铰链的 IOL。还评估了 IOL 轴向运动对白内障手术后短期屈光漂移的影响。

方法

这项回顾性对比研究纳入了接受超声乳化白内障吸除术联合非球面 IOL 植入术的连续患者。术后 4 天和 1 个月,通过眼前节光学相干断层扫描测量 IOL 深度(从角膜内皮到 IOL 表面的距离)和角膜曲率。比较各组 IOL 轴向运动、角膜曲率和显式屈光球镜等效(MRSE)的变化,并评估各镜片之间的相关性。

结果

42 例患者(42 只眼)植入带铰链的 IOL,42 例患者(42 只眼)植入无铰链的 IOL。带铰链的 IOL 在术后 4 天至 1 个月的轴向运动变化明显小于无铰链的 IOL(p<0.001)。带铰链的 IOL 的轴向运动与 MRSE 变化无关;然而,无铰链的 IOL 的向前移位与近视屈光变化相关(Pearson r=0.62,p<0.001)。

结论

白内障手术后 4 天至 1 个月,带铰链的 IOL 术后轴向运动比无铰链的 IOL 更稳定。尽管两种具有平面襻设计的研究性 IOL 均由类似的丙烯酸材料制成,但其他特征(如铰链结构)可能会影响 IOL 在囊袋中的稳定性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/98c4/9426912/f30386358cbb/pone.0273431.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验