Kaufmann Manuela E, Solderer Alex, Hofer Deborah, Schmidlin Patrick R
Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, CH-8032 Zurich, Switzerland.
Dent J (Basel). 2020 Jun 3;8(2):55. doi: 10.3390/dj8020055.
This case report describes a rare case of a broken periodontal probe tip and its removal. A male patient presented himself in June 2019 due to a painful tooth in the upper left quadrant. The patient elected treatment in the dental school's student course. In October 2019, in preparation for full-mouth rehabilitation, a complete diagnostic status was performed, including radiographs. In this context, a metal-dense fragment was identified in the apical region of the (missing) tooth 45. It was diagnosed as the broken tip of a periodontal probe (type AE P OWB). Since a PCP-12 probe is generally used in-house, iatrogenic damage during the initial examination or student course could be excluded a priori. The patient was not able to remember any treatment that could be associated with the instrument's breaking. Since the probe fragment was palpable and a translocation could not be precluded, the patient agreed to its removal under local anesthesia, after a cone-beam CT. This article describes and discusses this particular case, with special emphasis on iatrogenic instrument fractures and their removal.
本病例报告描述了一例罕见的牙周探针尖端折断及其取出的病例。一名男性患者于2019年6月因左上象限牙齿疼痛前来就诊。该患者选择在牙科学院的学生课程中接受治疗。2019年10月,为进行全口修复做准备,进行了包括X光片在内的全面诊断检查。在此过程中,在(缺失的)45号牙根尖区域发现了一个金属致密碎片。经诊断,其为牙周探针(AE P OWB型)的折断尖端。由于该机构内部通常使用PCP - 12探针,因此可以先验地排除初次检查或学生课程期间的医源性损伤。患者无法回忆起任何可能与器械折断相关的治疗过程。由于探针碎片可触及且不能排除移位情况,在进行锥形束CT扫描后,患者同意在局部麻醉下将其取出。本文描述并讨论了这一特殊病例,特别强调了医源性器械折断及其取出。