通过 10-5 和 10-20 系统定位用于神经刺激的手部初级运动皮层:一项 MRI 研究。

Localizing the Primary Motor Cortex of the Hand by the 10-5 and 10-20 Systems for Neurostimulation: An MRI Study.

机构信息

Federal University of Paraíba, João Pessoa, Brazil.

出版信息

Clin EEG Neurosci. 2021 Nov;52(6):427-435. doi: 10.1177/1550059420934590. Epub 2020 Jul 1.

Abstract

. The primary motor cortex of the hand (M1-Hand) is a target used in transcranial magnetic stimulation (TMS) and in transcranial direct current stimulation (tDCS) for the treatment and evaluation of motor neurological diseases. Magnetic resonance imaging-guided neuronavigation locates the M1-Hand with high precision, but at a high cost. Although less accurate, the C3/C4 points of the international 10-20 system (IS 10-20) are routinely used to locate the M1-Hand. The international 10-5 system (IS 10-5) was developed with additional points (C3h/C4h), which could make it more accurate, but has not yet been tested on the location of the M1-Hand. . To analyze and compare the accuracy of C1/C2, C3h/C4h and C3/C4 points in locating the M1-Hand correspondence on the scalp. . The authors comparatively analyzed the distances from points C1/C2, C3h/C4h, and C3/C4 to the correspondence of the M1-Hand on the scalp in 30 MRI head exams. . In most cases, the M1-Hand was located between C1-C3h and C2-C4h in the left and right hemispheres of the brain, respectively. The C3h (0.98 ± 0.49 cm) and C4h (0.98 ± 0.51 cm) points presented the shortest distances from the M1-Hand, with a significant difference when compared with C3/C4. The accuracy between C1/C2 and C3h/C4h was not statistically significant. . The C3h/C4h and C1/C2 points were more accurate when compared with the C3 and C4 points in locating the M1-Hand correspondence on the scalp.

摘要

. 手的初级运动皮层(M1-Hand)是经颅磁刺激(TMS)和经颅直流电刺激(tDCS)用于治疗和评估运动神经系统疾病的靶点。磁共振成像引导下的神经导航以高精度定位 M1-Hand,但成本较高。尽管不太准确,但国际 10-20 系统(IS 10-20)的 C3/C4 点通常用于定位 M1-Hand。国际 10-5 系统(IS 10-5)开发了额外的点(C3h/C4h),这可能使其更准确,但尚未在 M1-Hand 的定位上进行测试。. 分析和比较 C1/C2、C3h/C4h 和 C3/C4 点在头皮上定位 M1-Hand 对应点的准确性。. 作者比较分析了 30 例 MRI 头颅检查中 C1/C2、C3h/C4h 和 C3/C4 点到头皮上 M1-Hand 对应点的距离。. 在大多数情况下,M1-Hand 位于大脑左、右半球的 C1-C3h 和 C2-C4h 之间。C3h(0.98±0.49cm)和 C4h(0.98±0.51cm)点与 M1-Hand 的距离最短,与 C3/C4 相比差异有统计学意义。C1/C2 与 C3h/C4h 之间的准确性无统计学差异。. C3h/C4h 和 C1/C2 点在定位头皮上 M1-Hand 对应点时比 C3 和 C4 点更准确。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验