Guignier F, Domy M, Angue M, Richaud P, Chatelain P
Centre Régional de Transfusion Sanguine de Dijon, France.
Vox Sang. 1988;55(1):30-4. doi: 10.1111/j.1423-0410.1988.tb04684.x.
A solid-phase low-ionic strength salt antiglobulin test (LISS-SPAT) has been developed using a microplate coated with dried sera as a solid phase. Before coating, the in vitro C3d fragment generation was activated by adding heat-aggregated immunoglobulin. The LISS-SPAT was compared with low-ionic strength conventional antiglobulin test (LISS-AGT) and also with a test using polybrene or papain microplates. When detecting the IgG and IgM antierythrocyte antibodies the reaction was developed in the same way in LISS-SPAT and LISS-AGT. In routine work, the LISS-SPAT provides a fast, reliable, handy and inexpensive screening of antibodies. This method appears to be an additional method to the papain and polybrene tests in microplates.
一种固相低离子强度盐抗球蛋白试验(LISS-SPAT)已被开发出来,该试验使用涂有干燥血清的微孔板作为固相。在包被之前,通过添加热聚集免疫球蛋白激活体外C3d片段的产生。将LISS-SPAT与低离子强度传统抗球蛋白试验(LISS-AGT)以及使用聚凝胺或木瓜蛋白酶微孔板的试验进行了比较。在检测IgG和IgM抗红细胞抗体时,LISS-SPAT和LISS-AGT中的反应以相同方式进行。在常规工作中,LISS-SPAT提供了一种快速、可靠、方便且廉价的抗体筛查方法。该方法似乎是微孔板中木瓜蛋白酶和聚凝胺试验的一种补充方法。