Suppr超能文献

[优化临床血压测量的观察者表现:《柳叶刀》高血压委员会小组的立场声明 优化临床血压测量中观察者的表现:该小组的立场声明] (原文中存在部分重复和不完整表述,翻译尽量忠实原文)

[Optimizing observer performance of clinic blood Pressure measurement: a position statement from the Lancet Commission on Hypertension GroupOtimização do desempenho do observador na medição clínica da pressão arterial: posicionamento do Grupo da ].

作者信息

Padwal Raj, Campbell Norm R C, Schutte Aletta E, Olsen Michael Hecht, Delles Christian, Etyang Anthony, Cruickshank J Kennedy, Stergiou George, Rakotz Michael K, Wozniak Gregory, Jaffe Marc G, Benjamin Ivor, Parati Gianfranco, Sharman James E

机构信息

Departamento de Medicina, Universidad de Alberta Edmonton Canadá Departamento de Medicina, Universidad de Alberta, Edmonton (Canadá).

Departamento de Medicina, Fisiología y Farmacología y Salud Comunitaria, Instituto O'Brien de Salud Pública e Instituto Cardiovascular Libin de Alberta, Universidad de Calgary, Calgary Alberta Canadá Departamento de Medicina, Fisiología y Farmacología y Salud Comunitaria, Instituto O'Brien de Salud Pública e Instituto Cardiovascular Libin de Alberta, Universidad de Calgary, Calgary, Alberta (Canadá).

出版信息

Rev Panam Salud Publica. 2020 Jul 15;44:e88. doi: 10.26633/RPSP.2020.88. eCollection 2020.

Abstract

High blood pressure (BP) is a highly prevalent modifiable cause of cardiovascular disease, stroke, and death. Accurate BP measurement is critical, given that a 5-mmHg measurement error may lead to incorrect hypertension status classification in 84 million individuals worldwide. This position statement summarizes procedures for optimizing observer performance in clinic BP measurement, with special attention given to low-tomiddle- income settings, where resource limitations, heavy workloads, time constraints, and lack of electrical power make measurement more challenging. Many measurement errors can be minimized by appropriate patient preparation and standardized techniques. Validated semi-automated/automated upper arm cuff devices should be used instead of auscultation to simplify measurement and prevent observer error. Task sharing, creating a dedicated measurement workstation, and using semi-automated or solar-charged devices may help. Ensuring observer training, and periodic re-training, is critical. Low-cost, easily accessible certification programs should be considered to facilitate best BP measurement practice.

摘要

高血压是心血管疾病、中风和死亡的一个高度普遍且可改变的病因。鉴于5毫米汞柱的测量误差可能导致全球8400万人的高血压状态分类错误,准确测量血压至关重要。本立场声明总结了在临床血压测量中优化观察者表现的程序,特别关注低收入和中等收入地区,在这些地区,资源限制、工作量大、时间紧迫和电力短缺使测量更具挑战性。通过适当的患者准备和标准化技术,许多测量误差可以降至最低。应使用经过验证的半自动/自动上臂袖带设备代替听诊法,以简化测量并防止观察者误差。任务分担、创建专用测量工作站以及使用半自动或太阳能充电设备可能会有所帮助。确保观察者培训和定期再培训至关重要。应考虑低成本、易于获得的认证计划,以促进最佳血压测量实践。