Suppr超能文献

基于环介导等温扩增(LAMP)方法的新型即时检测(POCT)系统同时诊断登革热病毒、基孔肯雅热病毒和寨卡病毒感染。

Simultaneous diagnosis of dengue virus, Chikungunya virus, and Zika virus infection using a new point-of-care testing (POCT) system based on the loop-mediated isothermal amplification (LAMP) method.

机构信息

Disease Control and Prevention Center, National Center for Global Health and Medicine, 1-21-1 Toyama, Shinjuku-ku, Tokyo, Japan.

Disease Control and Prevention Center, National Center for Global Health and Medicine, 1-21-1 Toyama, Shinjuku-ku, Tokyo, Japan.

出版信息

J Infect Chemother. 2020 Dec;26(12):1249-1253. doi: 10.1016/j.jiac.2020.07.001. Epub 2020 Jul 24.

Abstract

INTRODUCTION

Dengue fever, Chikungunya fever, and Zika virus infection have similar symptoms and overlapping areas of endemicity and so cannot be distinguished clinically. Rapid diagnosis tests are available for each infection but each test covers only single target. There are PCR-based methods available that test for all three infections simultaneously, not applicable for in-vitro diagnostic use. The aim of this study was to evaluate the diagnostic accuracy of a new point-of-care testing (LAMP POCT) based on loop-mediated isothermal amplification method that tests for all three viruses simultaneously, using serum or urine samples, and takes about 45 min.

METHODS

LAMP POCT was evaluated as the comparator on 67 individuals, of whom 56 had dengue, three had Chikungunya, two had Zika virus infection and six did not have any kind of these infections confirmed by RT-PCR.

RESULTS

Among individuals with dengue, the sensitivity of LAMP POCT was 100% in samples collected in the first 3 days after illness onset, all three patients with Chikungunya were LAMP POCT positive, and both patients with Zika virus infection were LAMP POCT negative. There were no false-positive test results.

CONCLUSIONS

LAMP POCT has potential utility as a point-of-care combination test for dengue and Chikungunya viruses, but further prospective studies are needed among individuals with Chikungunya virus and Zika virus infection, using serum and urine samples.

摘要

简介

登革热、基孔肯雅热和寨卡病毒感染具有相似的症状,且流行区域重叠,因此无法在临床上进行区分。目前针对每种感染都有快速诊断检测方法,但每种检测方法都仅针对单一目标。也有基于 PCR 的方法可同时检测这三种感染,但不适用于体外诊断用途。本研究旨在评估一种新的即时检测(LAMP POCT)的诊断准确性,该检测方法基于环介导等温扩增法,可同时检测这三种病毒,使用血清或尿液样本,耗时约 45 分钟。

方法

LAMP POCT 作为比较方法在 67 名个体中进行了评估,其中 56 名患有登革热,3 名患有基孔肯雅热,2 名患有寨卡病毒感染,6 名个体未通过 RT-PCR 确诊患有这三种感染中的任何一种。

结果

在发病后 3 天内采集的登革热患者样本中,LAMP POCT 的敏感性为 100%,所有 3 名基孔肯雅热患者的检测结果均为阳性,而 2 名寨卡病毒感染患者的检测结果均为阴性。没有假阳性的检测结果。

结论

LAMP POCT 作为一种即时检测方法,具有检测登革热和基孔肯雅热病毒的潜力,但需要在基孔肯雅热和寨卡病毒感染患者中,使用血清和尿液样本,进一步开展前瞻性研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验