Kang Ju-Young, Lee Seo-Hyun, Jo Ah-Hyeon, Park Eun-Ji, Bak Young-Seok, Kim Jung-Beom
Department of Food Science and Technology, Suncheon National University, Suncheon, 57922 Republic of Korea.
Department of Emergency Medical Services, Sun Moon University, Asan-si, Chungcheongnam-do, 31460 Republic of Korea.
Food Sci Biotechnol. 2020 May 30;29(9):1289-1294. doi: 10.1007/s10068-020-00778-8. eCollection 2020 Sep.
This study was undertaken to improve the detection accuracy for coliform bacteria, by analyzing biochemical properties of false positive and false negative colonies isolated from two dry rehydratable film methods, 3 M™ Petrifilm™ /Coliform count (PCC) and MC-Media Pad coliform count (MCC). The detection accuracy of PCC and MCC was determined to be 99.4% and 97.9%, respectively, with the detection error being 0.6% and 2.1%, respectively. False positive colonies (red colony without gas) on PCC were identified as and . All false positive colonies on MCC were identified as ; this organism gives a positive oxidase test, whereas coliform bacteria are oxidase negative. In conclusion, we propose that for improving detection accuracy of coliform bacteria, the incubation time of PCC should be modified and increased from 24 h to 48 h, and the oxidase test of MCC isolates should be included in the Korea Food Code.
本研究旨在通过分析从两种干式复水膜方法(3M™ Petrifilm™/大肠菌群计数(PCC)和MC-培养基平板大肠菌群计数(MCC))中分离出的假阳性和假阴性菌落的生化特性,提高大肠菌群的检测准确性。PCC和MCC的检测准确率分别为99.4%和97.9%,检测误差分别为0.6%和2.1%。PCC上的假阳性菌落(无气体的红色菌落)被鉴定为 和 。MCC上的所有假阳性菌落均被鉴定为 ;这种微生物氧化酶试验呈阳性,而大肠菌群氧化酶试验呈阴性。总之,我们建议,为提高大肠菌群的检测准确性,应将PCC的培养时间从24小时延长至48小时,并在《韩国食品法典》中纳入对MCC分离株的氧化酶试验。