Suppr超能文献

使用、再利用或丢弃:2019年冠状病毒病大流行期间,经汽化过氧化氢消毒后N95呼吸器完整性的定量定义差异

Use, reuse or discard: quantitatively defined variance in N95 respirator integrity following vaporized hydrogen peroxide decontamination during the COVID-19 pandemic.

作者信息

Levine Carly, Grady Courtney, Block Thomas, Hurley Harry, Russo Riccardo, Peixoto Blas, Frees Alexis, Ruiz Alejandro, Alland David

出版信息

medRxiv. 2020 Aug 21:2020.08.18.20177071. doi: 10.1101/2020.08.18.20177071.

Abstract

BACKGROUND

COVID-19 has stretched the ability of many institutions to supply needed personal protective equipment, especially N95 respirators. N95 decontamination and reuse programs provide one potential solution to this problem. Unfortunately, a comprehensive evaluation of the effects of decontamination on the integrity of various N95 models using a quantitative fit test (QTFT) approach is lacking.

AIMS

  1. To investigate the effects of up to eight rounds of vaporized H2O2 (VHP) decontamination on the integrity of N95 respirators currently in use in a hospital setting. 2) To examine if N95 respirators worn by one user can adapt to the face shape of a second user with no compromise of integrity following VHP decontamination.

METHODS

The PortaCount Pro+ Respirator Fit Tester Model 8038 was used to quantitatively define the integrity, measured by fit, of N95 respirators following decontamination with VHP.

FINDINGS

There was an observable downward trend in the integrity of Halyard Fluidshield 46727 N95 respirators throughout eight cycles of decontamination with VHP. The integrity of 3M 1870 N95 respirators was significantly reduced after the respirator was worn, decontaminated with VHP, and then quantitatively fit tested on a second user. Furthermore, we uncovered inconsistencies between qualitative fit test and QTFT results that may have strong implications on the fit testing method used by institutions.

CONCLUSIONS

Our data revealed variability in the integrity of different N95 models after VHP decontamination and exposed potential limitations of N95 decontamination and reuse programs.

摘要

背景

新型冠状病毒肺炎疫情使许多机构供应所需个人防护装备(尤其是N95口罩)的能力达到极限。N95口罩去污和再利用计划为解决这一问题提供了一种潜在方案。遗憾的是,目前缺乏对使用定量适合性测试(QTFT)方法去污对各种N95型号完整性影响的全面评估。

目的

1)研究多达八轮汽化过氧化氢(VHP)去污对医院环境中目前使用的N95口罩完整性的影响。2)检查一名使用者佩戴过的N95口罩在经过VHP去污后,能否适应第二名使用者的脸型且不影响其完整性。

方法

使用PortaCount Pro+ 8038型呼吸器适合性测试仪,通过适合性定量测定VHP去污后N95口罩的完整性。

研究结果

在对Halyard Fluidshield 46727 N95口罩进行八轮VHP去污的整个过程中,其完整性呈现出明显的下降趋势。3M 1870 N95口罩在被一名使用者佩戴、经VHP去污后,再对第二名使用者进行定量适合性测试时,其完整性显著降低。此外,我们还发现定性适合性测试与QTFT结果之间存在不一致,这可能对机构使用的适合性测试方法有重大影响。

结论

我们的数据揭示了VHP去污后不同N95型号完整性的差异,并暴露了N95去污和再利用计划的潜在局限性。

相似文献

6
N95 respirator decontamination: a study in reusability.N95 口罩消毒:可重复使用性研究
Mater Today Adv. 2021 Sep;11:100148. doi: 10.1016/j.mtadv.2021.100148. Epub 2021 Jun 23.
8
Hydrogen peroxide vapor decontamination of N95 respirators for reuse.过氧化氢蒸汽对 N95 口罩进行再处理消毒。
Infect Control Hosp Epidemiol. 2022 Jan;43(1):45-47. doi: 10.1017/ice.2021.48. Epub 2021 Feb 9.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验