Department of Ophthalmology, Chung-Ang University College of Medicine, Chung-Ang University Hospital, 102 Heukseok-ro, Dongjak-gu, Seoul, 06973, Korea.
Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.
Sci Rep. 2020 Sep 3;10(1):14554. doi: 10.1038/s41598-020-71098-4.
The evaluation of proptosis is essential for the diagnosis of orbital disease. We have developed a computed tomography (CT)-based three-dimensional (3D) reconstruction software to measure the degree of proptosis. To verify clinical usefulness and reliability, the degree of proptosis was measured in 126 patients with Graves' orbitopathy (GO) with 3D reconstruction software and compared with those obtained with Hertel exophthalmometer and CT. The proptosis values measured by 3D reconstruction software, CT, and Hertel exophthalmometer were closely related to each other, but showed significant differences (p < 0.001). In contrast, the amount of change in proptosis after orbital decompression were not different among the three measurements (p = 0.153). The intra-observer correlation coefficients of the 3D reconstruction software, CT, and Hertel exophthalmometer measurements were 0.997, 0.942, and 0.953, respectively. In patients with strabismus, the intra-observer correlation coefficient of CT and Hertel exophthalmometer decreased to 0.895 and 0.920, respectively, but the intra-observer correlation coefficient of the 3D reconstruction software did not change to 0.996. The inter-observer correlation coefficients of CT and 3D reconstruction software for three different ophthalmologists were 0.742 and 0.846, respectively. In conclusion, the measurement of proptosis by 3D reconstruction software seems to be a reliable method, especially in the presence of eyeball deviation.
突眼的评估对于眼眶疾病的诊断至关重要。我们开发了一种基于计算机断层扫描(CT)的三维(3D)重建软件来测量突眼程度。为了验证临床实用性和可靠性,我们使用 3D 重建软件测量了 126 例格雷夫斯眼病(GO)患者的突眼程度,并与 Hertel 突眼计和 CT 测量值进行了比较。3D 重建软件、CT 和 Hertel 突眼计测量的突眼值彼此密切相关,但存在显著差异(p<0.001)。相比之下,三种测量方法的眼眶减压术后突眼量变化无差异(p=0.153)。3D 重建软件、CT 和 Hertel 突眼计测量的观察者内相关系数分别为 0.997、0.942 和 0.953。在斜视患者中,CT 和 Hertel 突眼计的观察者内相关系数分别降至 0.895 和 0.920,但 3D 重建软件的观察者内相关系数不变,仍为 0.996。三位不同眼科医生的 CT 和 3D 重建软件的观察者间相关系数分别为 0.742 和 0.846。总之,3D 重建软件测量突眼似乎是一种可靠的方法,尤其是在眼球偏斜的情况下。