Laboratoire d'Imagerie Biomédicale, LIB, INSERM, CNRS, Sorbonne Université, 15 rue de l'école de médecine, 75006, Paris, France.
PARCC, INSERM, Université de Paris, 75015, Paris, France.
Int J Cardiovasc Imaging. 2021 Feb;37(2):663-674. doi: 10.1007/s10554-020-02040-y. Epub 2020 Sep 27.
To evaluate right ventricle (RV) diastolic function from phase-contrast MRI (PC-MRI) in aging. 89 healthy individuals (50 men, 43 ± 15 years) underwent cardiac MRI including 2D PC-MRI (1.5T) and reference Doppler echocardiography of both ventricles on the same day. Conventional echocardiographic parameters were estimated: early (E, cm/s) and atrial (A) peak velocities as well as myocardial early peak longitudinal velocity (E'). PC-MRI images were analyzed using custom software, providing: E', E and A waves along with respective peak flow rates (Ef, Af, mL/s) and filling volume (mL), for both ventricles. Intra- and inter-observer reproducibility was studied in 30 subjects and coefficients of variation (CoV) as well as intra-class correlation coefficients (ICC) were provided. RV diastolic function indices derived from PC-MRI data were reproducible (CoV ≤ 21%, ICC ≥ 0.75) and reliable as reflected by significant associations with left ventricular diastolic function indices assessed using both echocardiography (linear regression Pearson correlation coefficient r ≤ 0.59) and PC-MRI (r ≤ 71). Despite the fair associations between RV echocardiography and PC-MRI (r ≤ 0.25), the highest correlation with age was obtained for MRI Ef/Af ratio (r = - 0.64, p < 0.0001 vs. r = - 0.40, p = 0.0001 for echocardiographic E/A). Among PC-MRI E/A ratios, highest correlations with age were observed for flow rate and mean velocity ratios (r = - 0.61, p < 0.0001) as compared to maximal velocity ratios (r = - 0.56, p < 0.0001). Associations with age for E' were equivalent between PC-MRI (mean velocity: r = - 0.40, p < 0.0001; maximal velocity: r = - 0.36, p = 0.0005) and echocardiography (r = - 0.36, p = 0.0006). Finally, the significant and age-independent associations between RV mass/end-diastolic volume and E' were stronger for PC-MRI (mean velocity: r = - 0.36, p = 0.0006; maximal velocity: r = - 0.28, p = 0.007) than echocardiography (r = - 0.09, p = 0.38). PC-MRI tricuspid inflow and annulus myocardial velocity parameters were reproducible and able to characterize age-related variations in RV diastolic function.
从相位对比 MRI(PC-MRI)评估老年人右心室(RV)舒张功能。89 名健康个体(50 名男性,43±15 岁)在同一天接受了包括二维 PC-MRI(1.5T)和两个心室的参考多普勒超声心动图的心脏 MRI。估计了常规超声心动图参数:早期(E,cm/s)和心房(A)峰值速度以及心肌早期峰值纵向速度(E')。使用定制软件分析 PC-MRI 图像,提供了两个心室的 E'、E 和 A 波以及各自的峰值流速(Ef、Af、mL/s)和充盈量(mL)。在 30 名受试者中研究了观察者内和观察者间的可重复性,并提供了变异系数(CoV)和组内相关系数(ICC)。从 PC-MRI 数据得出的 RV 舒张功能指数具有可重复性(CoV≤21%,ICC≥0.75),并且通过与使用超声心动图(线性回归 Pearson 相关系数 r≤0.59)和 PC-MRI(r≤0.71)评估的左心室舒张功能指数的显著相关性得到验证。尽管 RV 超声心动图和 PC-MRI 之间存在一定的相关性(r≤0.25),但与年龄相关性最高的是 MRI Ef/Af 比值(r=-0.64,p<0.0001,r=-0.40,p=0.0001)。在 PC-MRI 的 E/A 比值中,与年龄相关性最高的是流速和平均速度比值(r=-0.61,p<0.0001),而不是最大速度比值(r=-0.56,p<0.0001)。E'与年龄的相关性在 PC-MRI(平均速度:r=-0.40,p<0.0001;最大速度:r=-0.36,p=0.0005)和超声心动图(r=-0.36,p=0.0006)之间是等效的。最后,与 RV 质量/舒张末期容积相关的 RV 质量/舒张末期容积与 E'之间的显著、与年龄无关的相关性在 PC-MRI(平均速度:r=-0.36,p=0.0006;最大速度:r=-0.28,p=0.007)中强于超声心动图(r=-0.09,p=0.38)。PC-MRI 三尖瓣流入和瓣环心肌速度参数具有可重复性,能够描述 RV 舒张功能与年龄相关的变化。