二维及实时三维经食管超声心动图评估机械二尖瓣人工瓣环内径和面积的正常值。

Normal reference values for mechanical mitral prosthetic valve inner diameters and areas assessed by two-dimensional and real-time three-dimensional transesophageal echocardiography.

机构信息

Faculty of Medicine, Department of Cardiology, Hitit University, Buharaevler Mah. Buhara 25. Sok. No:1 /A Daire:22, Çorum, Turkey.

Department of Cardiology, Koşuyolu Kartal Heart Training and Research Hospital, Istanbul, Turkey.

出版信息

Int J Cardiovasc Imaging. 2021 Feb;37(2):547-557. doi: 10.1007/s10554-020-02039-5. Epub 2020 Oct 3.

DOI:10.1007/s10554-020-02039-5
PMID:33011903
Abstract

It was previously observed that two dimensional (2D) Doppler derived and real-time three-dimensional (RT-3D) directly measured valve areas were smaller than reported manufacturer sizes. It may be helpful to obtain the ranges of inner diameters (IDs) and the geometric orifice area (GOA) during evaluation of prosthetic mitral valves. In this study, we aimed to provide reference dimensional parameters of bileflet mitral mechanical prosthetic valves. Patients with recent mitral valve replacement were examined by 2D and RT-3D transesophageal echocardiography (TEE) in the early postoperative period when the presence of pannus overgrowth was unlikely. Measurements of 2D IDs, 3D hinge to hinge (HHD) and edge to edge diameters (EED) and 3D GOA were obtained and compared with reported manufacturer sizes and areas. This study enrolled 126 patients with mitral prosthetic valves (38 ATS, 42 Carbomedics, 46 St. Jude Medical, all bileaflet). The measured 2D and 3D IDs and GOA were significantly smaller than reported manufacturer sizes in the majority of the valve sizes. This RT-3D TEE-guided study provides ranges of reference values for directly measured IDs and GOA of the three most commonly used mechanical mitral prosthetic valve types for the first time in a relatively large series.

摘要

先前观察到,二维(2D)多普勒衍生和实时三维(RT-3D)直接测量的瓣膜面积小于制造商报告的尺寸。在评估二尖瓣机械人工瓣膜时,获得内径(ID)范围和几何瓣口面积(GOA)可能会有所帮助。在这项研究中,我们旨在提供双叶二尖瓣机械人工瓣膜的参考尺寸参数。近期行二尖瓣置换术的患者在术后早期接受二维和 RT-3D 经食管超声心动图(TEE)检查,此时不太可能存在赘生物过度生长。测量二维 ID、3D 铰链到铰链(HHD)和边缘到边缘直径(EED)以及 3D GOA,并与制造商报告的尺寸和面积进行比较。本研究纳入了 126 例二尖瓣人工瓣膜患者(38 例 ATS、42 例 Carbomedics、46 例 St. Jude Medical,均为双叶瓣)。在大多数瓣膜尺寸中,测量的二维和三维 ID 和 GOA 明显小于制造商报告的尺寸。这项 RT-3D TEE 引导研究首次在相对较大的系列中提供了三种最常用的二尖瓣机械人工瓣膜类型的直接测量 ID 和 GOA 的参考值范围。

相似文献

1
Normal reference values for mechanical mitral prosthetic valve inner diameters and areas assessed by two-dimensional and real-time three-dimensional transesophageal echocardiography.二维及实时三维经食管超声心动图评估机械二尖瓣人工瓣环内径和面积的正常值。
Int J Cardiovasc Imaging. 2021 Feb;37(2):547-557. doi: 10.1007/s10554-020-02039-5. Epub 2020 Oct 3.
2
Evaluation of mechanical prosthetic valves: the role of three dimensional echocardiography in calculating effective orifice area in obese vs non-obese individuals.评估机械人工瓣膜:三维超声心动图在计算肥胖与非肥胖个体有效瓣口面积中的作用。
Int J Cardiovasc Imaging. 2021 Jan;37(1):215-227. doi: 10.1007/s10554-020-01978-3. Epub 2020 Aug 24.
3
Characteristic localization patterns of thrombus on various brands of bileaflet mitral mechanical heart valves as assessed by three-dimensional transesophageal echocardiography and their relationship with thromboembolism.经三维经食管超声心动图评估的不同品牌双叶机械二尖瓣血栓的特征性定位模式及其与血栓栓塞的关系。
Int J Cardiovasc Imaging. 2021 Sep;37(9):2691-2705. doi: 10.1007/s10554-021-02234-y. Epub 2021 Apr 9.
4
Comparison of the effective orifice area of prosthetic mitral valves using two-dimensional versus three-dimensional transesophageal echocardiography.二维与三维经食管超声心动图比较人工二尖瓣有效瓣口面积。
J Int Med Res. 2021 Mar;49(3):300060521997621. doi: 10.1177/0300060521997621.
5
[Three-dimensional transesophageal echocardiographic assessment for prosthetic valves].[人工心脏瓣膜的三维经食管超声心动图评估]
Nihon Kyobu Geka Gakkai Zasshi. 1997 Aug;45(8):1084-9.
6
Echocardiography-Guided Novel Transcatheter Approach for Frozen Cusp of Mitral Bioprosthesis.超声心动图引导下二尖瓣生物瓣冻结瓣叶的新型经导管治疗方法
JACC Cardiovasc Interv. 2020 Jul 13;13(13):e123-e126. doi: 10.1016/j.jcin.2020.02.024. Epub 2020 Apr 15.
7
Direct assessment of normal mechanical mitral valve orifice area by real-time 3D echocardiography.通过实时三维超声心动图直接评估正常机械二尖瓣口面积。
JACC Cardiovasc Imaging. 2012 May;5(5):478-83. doi: 10.1016/j.jcmg.2011.06.024.
8
New recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound.超声心动图和多普勒超声评估人工瓣膜的新建议。
Methodist Debakey Cardiovasc J. 2010 Jan-Mar;6(1):20-6. doi: 10.14797/mdcj-6-1-20.
9
Thrombosis of a bileaflet prosthetic mitral valve: a real-time three-dimensional transesophageal echocardiography perspective.双叶人工二尖瓣血栓形成:实时三维经食管超声心动图视角。
Int J Cardiovasc Imaging. 2010 Apr;26(4):367-8. doi: 10.1007/s10554-009-9548-9. Epub 2009 Dec 10.
10
Changes in mitral annular geometry after aortic valve replacement: a three-dimensional transesophageal echocardiographic study.主动脉瓣置换术后二尖瓣环几何形状的变化:一项三维经食管超声心动图研究
J Heart Valve Dis. 2012 Nov;21(6):696-701.

引用本文的文献

1
Novel TrueVue series of 3D echocardiography: Revealing the pathological morphology of congenital heart disease.新型TrueVue系列三维超声心动图:揭示先天性心脏病的病理形态
Front Physiol. 2022 Sep 6;13:1000007. doi: 10.3389/fphys.2022.1000007. eCollection 2022.

本文引用的文献

1
Characterization of Effective Orifice Areas of Mitral Prosthetic Heart Valves: An In-Vitro Study.二尖瓣人工心脏瓣膜有效瓣口面积的特征:一项体外研究。
J Heart Valve Dis. 2017 Nov;26(6):677-687.
2
A global perspective on mechanical prosthetic heart valve thrombosis: Diagnostic and therapeutic challenges.机械人工心脏瓣膜血栓形成的全球视角:诊断与治疗挑战
Anatol J Cardiol. 2016 Dec;16(12):980-989. doi: 10.14744/AnatolJCardiol.2016.7486.
3
Diagnosis of the prosthetic heart valve pannus formation with real-time three-dimensional transoesophageal echocardiography.
经食管实时三维超声心动图诊断人工心脏瓣膜血管翳形成
Eur J Echocardiogr. 2010 May;11(4):E17. doi: 10.1093/ejechocard/jep206. Epub 2009 Dec 17.
4
CarboMedics mechanical prosthesis: performance at eight years.卡博梅迪克斯机械假体:八年性能表现
J Heart Valve Dis. 2000 Sep;9(5):678-87.