Suppr超能文献

VO2 Master Pro用于耗氧量和通气评估的有效性和可靠性

Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment.

作者信息

Montoye Alexander H K, Vondrasek Joseph D, Hancock James B

机构信息

Department of Integrative Physiology and Health Science, Alma College, Alma, MI, USA.

Department of Education, Alma College, Alma, MI, USA.

出版信息

Int J Exerc Sci. 2020 Sep 1;13(4):1382-1401. doi: 10.70252/THJT1177. eCollection 2020.

Abstract

This study assessed validity and reliability of the VO Master Pro portable metabolic analyzer for assessment of oxygen consumption (VO) and minute ventilation (VE). In Protocol 1, eight male participants (height: 182.6 ± 5.8 cm, weight: 79.6 ± 8.3 kg, age: 41.0 ± 12.3 years) with previous competitive cycling experience completed an hour-long stationary cycling protocol twice, progressing from 100-300 Watts every 10 minutes while wearing the VO Master and a criterion measure (Parvomedics) for five minutes each, at each stage. In Protocol 2, 16 recreationally active male participants (height: 168.2 ± 8.4 cm, weight: 76.5 ± 13.3 kg, age: 23.0 ± 9.4 years) completed three incremental, maximal stationary cycling tests wearing one of three analyzers for each test (VO Master version 1.1.1, VO Master version 1.2.1, Parvomedics). For Protocol 1 and convergent validity, the VO Master had mean absolute differences from the Parvomedics of <0.3 L/min for absolute VO and <5 L/min for VE overall and at each exercise stage. Mean absolute percent differences (MAPD) for VO and VE were <9% overall and <12% at each stage. Test-retest reliability of the VO Master (MAPD: 8.9-10.9%) was somewhat poorer than the Parvomedics (MAPD: 5.3-7.6%). For Protocol 2, validity was similar for both VO Master models (MAPD ~12% overall) compared to the Parvomedics for VO and VE. The VO Master had an acceptable validity and test-retest reliability for most intensities tested and may be an appealing option for field-based VO and VE analysis.

摘要

本研究评估了VO Master Pro便携式代谢分析仪在评估耗氧量(VO)和分钟通气量(VE)方面的有效性和可靠性。在方案1中,八名有过自行车竞赛经验的男性参与者(身高:182.6±5.8厘米,体重:79.6±8.3千克,年龄:41.0±12.3岁),穿着VO Master和一种标准测量设备(Parvomedics),每次在每个阶段进行五分钟的测试,以每十分钟从100瓦递增到300瓦的强度,完成了两次长达一小时的固定自行车测试。在方案2中,16名有休闲运动习惯的男性参与者(身高:168.2±8.4厘米,体重:76.5±13.3千克,年龄:23.0±9.4岁),每次测试佩戴三种分析仪之一(VO Master版本1.1.1、VO Master版本1.2.1、Parvomedics),完成了三次递增的最大强度固定自行车测试。对于方案1和收敛效度,VO Master与Parvomedics相比,绝对VO的平均绝对差异<0.3升/分钟,总体及每个运动阶段的VE平均绝对差异<5升/分钟。VO和VE的平均绝对百分比差异(MAPD)总体<9%,每个阶段<12%。VO Master的重测信度(MAPD:8.9 - 10.9%)略低于Parvomedics(MAPD:5.3 - 7.6%)。对于方案2,与Parvomedics相比,两种VO Master型号的效度相似(VO和VE的总体MAPD约为12%)。对于大多数测试强度,VO Master具有可接受的效度和重测信度,可能是现场VO和VE分析的一个有吸引力的选择。

相似文献

1
Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment.
Int J Exerc Sci. 2020 Sep 1;13(4):1382-1401. doi: 10.70252/THJT1177. eCollection 2020.
4
Validity and Reliability of the New Portable Metabolic Analyzer PNOE.
Front Sports Act Living. 2019 Sep 10;1:24. doi: 10.3389/fspor.2019.00024. eCollection 2019.
9
Cardiopulmonary parameters and organ blood flows for workers expressed in terms of VO2 for use in physiologically based toxicokinetic modeling.
J Toxicol Environ Health A. 2022 Apr 18;85(8):307-335. doi: 10.1080/15287394.2021.2006845. Epub 2022 Jan 6.
10
Validation of magnetic resonance imaging-derived venous oxygen saturation and oxygen consumption measurements during exercise.
Am J Physiol Heart Circ Physiol. 2025 Jun 1;328(6):H1179-H1192. doi: 10.1152/ajpheart.00134.2025. Epub 2025 Apr 18.

引用本文的文献

1
Reliability of Muscle Oxygen Saturation for Evaluating Exercise Intensity and Knee Joint Load Indicators.
J Funct Morphol Kinesiol. 2025 Apr 17;10(2):136. doi: 10.3390/jfmk10020136.
3
Validation of a tri-axial accelerometer for measuring physical activity in patients with subacute stroke.
Front Rehabil Sci. 2025 Jan 9;5:1496515. doi: 10.3389/fresc.2024.1496515. eCollection 2024.
4
Differences in Cardiorespiratory Responses with Three Set-Paced Submaximal Endurance Tests in Community-Dwelling Older Adults.
Int J Exerc Sci. 2024 Jul 1;17(4):1026-1037. doi: 10.70252/PYAW2914. eCollection 2024.
5
Feasibility of a Novel Augmented 6-Minute Incremental Step Test: A Simplified Cardiorespiratory Fitness Assessment Tool.
JACC Adv. 2024 Jul 8;3(8):101079. doi: 10.1016/j.jacadv.2024.101079. eCollection 2024 Aug.
7
Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity.
Front Sports Act Living. 2023 Aug 4;5:1143393. doi: 10.3389/fspor.2023.1143393. eCollection 2023.
9
Physiological and Mechanical Responses to a Graded Exercise Test in Traditional Rowing.
Int J Environ Res Public Health. 2023 Feb 18;20(4):3664. doi: 10.3390/ijerph20043664.
10
Enhancing instantaneous oxygen uptake estimation by non-linear model using cardio-pulmonary physiological and motion signals.
Front Physiol. 2022 Aug 25;13:897412. doi: 10.3389/fphys.2022.897412. eCollection 2022.

本文引用的文献

1
Ethical Issues Relating to Scientific Discovery in Exercise Science.
Int J Exerc Sci. 2020 Sep 1;12(1):1-8. doi: 10.70252/EYCD6235. eCollection 2019.
2
Validity, reliability and minimum detectable change of COSMED K5 portable gas exchange system in breath-by-breath mode.
PLoS One. 2018 Dec 31;13(12):e0209925. doi: 10.1371/journal.pone.0209925. eCollection 2018.
3
Open-circuit respirometry: a historical review of portable gas analysis systems.
Eur J Appl Physiol. 2017 Dec;117(12):2369-2386. doi: 10.1007/s00421-017-3716-8. Epub 2017 Oct 17.
4
Validity of Consumer-Based Physical Activity Monitors for Specific Activity Types.
Med Sci Sports Exerc. 2016 Aug;48(8):1619-28. doi: 10.1249/MSS.0000000000000933.
5
Portable open-circuit spirometry systems.
J Sports Med Phys Fitness. 2017 Mar;57(3):227-237. doi: 10.23736/S0022-4707.16.06049-7. Epub 2016 Feb 10.
6
False discovery rate control is a recommended alternative to Bonferroni-type adjustments in health studies.
J Clin Epidemiol. 2014 Aug;67(8):850-7. doi: 10.1016/j.jclinepi.2014.03.012. Epub 2014 May 13.
8
Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system.
Eur J Appl Physiol. 2012 Jul;112(7):2539-47. doi: 10.1007/s00421-011-2230-7. Epub 2011 Nov 11.
10
Validity and reliability of the Cortex MetaMax3B portable metabolic system.
J Sports Sci. 2010 May;28(7):733-42. doi: 10.1080/02640410903582776.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验